Connections
15
Connections using a Tripix Power IP66 PSU
Warning! Make sure that the total current draw of all the
devices that are supplied with DC power by one Tripix
Power IP66 will not exceed 5 A.
To connect the VC-Feeder to DMX data and DC power from a Martin
Tripix Power IP66:
1. Check that the system is isolated from AC mains power.
2. See Figure 5. Connect a Martin Hybrid Lead-in Cable, Tripix Power
IP66, P/N 11840195 to a DMX link from a DMX/RDM controller and to
the DC output of a Martin Tripix Power IP66.
3. Connect the Hybrid Lead-in Cable, Tripix Power IP66 to the VC-
Feeder IN connector. If necessary, add IP65 extension cable (see
”Extension cables” on page 13) between the Input Adapter Cable and
the VC-Feeder IN connector.
Figure 5: Hybrid Lead-in Cable, Tripix Power IP66, P/N 11840195
DC power from
5-pin male XLR
IP65 VC-Feeder connector
Tripix Power IP66
DMX from
DMX/RDM
controller
Power and DMX
to VC Feeder
IN connector