Basic service
Before servicing the JEM ZR series machines, read and observe all the
precautions listed in “Safety information” on page 5. Any service not described in
this section must be carried out by a Martin authorized service technician.
To find your local Martin service center visit
Cleaning
Excessive dust, fog fluid, and dirt build-up will degrade performance and cause
overheating and damage to the machine that is not covered by the product
warranty. To maintain adequate cooling, dust must be cleaned from the outer
casing and air vents of the machine periodically.
Isolate the machine from power and allow to cool completely before cleaning.
The fog output nozzles remain hot for a period after use.
•
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
•
Clean fog fluid residues from the fog output of the machine using a
damp cloth.
•
Clean the outer casing with a damp cloth only.
Martin Pro-Clean and Storage Fluid
Martin Pro-Clean & Storage Fluid
is specially designed for optimizing
performance while providing longevity of any effect machine. Martin Pro-Clean &
Storage fluid is the ultimate cleaning solution for Martin atmospheric effect heat
exchangers. This advanced preventative maintenance fluid has been utilized by
Martin service technicians for years of both cleaning and storing effect
machines. Utilizing Martin Pro-Clean & Storage Fluid
on a regular basis reduces
clogging and further extends the life of your Martin atmospheric effect machines.
By using the highest grade chemicals available while remaining eco-friendly,
Martin fluids are both effective and safe.
Instructions for use
Use fluid directly from container,
do not dilute
. Remove cap and safety seal; if
inner safety seal has been tampered with, return product to point of purchase.
Disconnect effect machine from power source before filling reservoir. When
possible, remove reservoir from machine and carefully fill reservoir to desired
level, taking care not to overfill or spill. Wipe up any spilled fluid with a damp
cloth. Replace cap on container and store upright in a secure location.
Cleaning and Preventative Maintenance Procedure:
Use Martin Pro Clean and Storage Fluid after every 200 hours of operation or
monthly depending on usage and duty cycle. In a well-ventilated area
temporarily connect Martin Pro Clean and Storage Fluid to the effect machine
being serviced or fill the machines provided fluid reservoir. Allow the machine to
fully heat. When machine is ready activate the machine to run continuously for
30-45 minutes; use a timer function if available.