background image

Safety information 

 

Check that all external covers and rigging hardware are securely 
fastened. 

 

Block access below the work area and work from a stable platform 
whenever installing, servicing or moving the machine. 

 

Do not operate the machine with missing or damaged covers or shields. 

 

In the event of an operating problem, stop using the machine 
immediately and disconnect it from power. Do not attempt to use a 
machine that is obviously damaged. 

 

Do not modify the machine in any way not described in this manual or 
install other than genuine Martin parts. 

 

Refer any service operation not described in this manual to a qualified 
technician. 

 

Fog output can cause condensation. Do not point the output at smooth 
floors. Floors and surfaces may become slippery. Check these 
frequently and wipe dry as necessary to avoid any danger of slipping. 

 

Ensure at least 2 m (6.6 ft.) visibility in areas where fog is being 
produced. 

 

Fog fluid contains food-grade glycols in solution that may present health 
risks. 

IF SWALLOWED:

 Do not induce vomiting. Drink 1-2 glasses of water 

and seek medical attention.  

AVOID CONTACT WITH SKIN AND EYES:

 In case of accidental 

contact: 

EYES:

 Hold eyes open and flush with water for ten minutes, 

seek medical attention if irritation persists. 

SKIN:

 Remove contaminated 

clothing and rinse skin for 20 minutes, seek medical attention if irritation 
persists. 
Consult the fluids' SDS for more detailed safety information at 

www.martin.com/support/compliance

 

 

This machine is not intended for use by persons (including children) 
with reduced physical sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision or 
instruction concerning use of the machine by a person responsible for 
their safety. Children should be supervised to ensure that they do not 
play with the machine. 

Preventing breathing problems 

 

A machine can operate safely only with the fog fluid it is designed for. 
Use the machine only with fluids specified under “Approved Fog Fluid 

types” on page 22 or you may cause the release of toxic gases, 
presenting a severe health hazard. You will also probably damage the 
machine. 

 

Do not create dense fog in confined or poorly ventilated areas. 

 

Do not expose people with health problems (including allergic and/or 
respiratory conditions such as asthma) to fog output. 

 

Do not point fog output directly at a person’s face or at face height. 

 
For the latest user documentation and other information for this and all Martin 
products, please visit the Martin website at

 www.martin.com 

 

If you have any questions about how to install, operate or service the fixture 
safely, please contact your Martin distributor, dealer or contact Martin Service 
and Support.  

Summary of Contents for Martin JEM ZR Series

Page 1: ...user manual READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...Dimensions Legal All dimensions are in millimeters...

Page 3: ...quential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Martin and JEM are registered trademarks of HARMAN PROFE...

Page 4: ...ut density 15 Setting the Timer 16 Using the Settings menu 16 Setting the DMX start address 16 Display back light setting 16 Setting the host client link mode 17 Priming the machine after fluid out 17...

Page 5: ...ctric shocks Always ground earth the machine electrically Use only a source of AC power that complies with local building and electrical codes and that has both overload and ground fault protection Be...

Page 6: ...and rating specified in this manual for the machine Provide a minimum free space of 100 mm 4 in around the machine Provide a minimum free space of 500 mm 20 in around fans and air vents and ensure fr...

Page 7: ...s SKIN Remove contaminated clothing and rinse skin for 20 minutes seek medical attention if irritation persists Consult the fluids SDS for more detailed safety information at www martin com support co...

Page 8: ...and used at a distance or the machines may be operated by DMX with full RDM capability for remote setup and status monitoring This manual contains instructions for all machines in the range but some...

Page 9: ...witch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse Product details ZR25 Fog output nozzle WARNING High temperature vapour and surfaces If su...

Page 10: ...itch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse ZR35 Fog output nozzle WARNING High temperature vapour and surfaces If suspending overhead...

Page 11: ...s power switch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse ZR45 Fog output nozzle WARNING High temperature vapour and surfaces If suspendin...

Page 12: ...ear of the unit to the ON I position The display will show HEAT If the display shows OFF press the FOG button on the control panel or set the RUN MODE to CONTINUOUS After about 6 8 minutes the display...

Page 13: ...ing bolts fitted to the hanging bracket in place of the normal hand wheel bolts Before first use remove the shipping bolts and replace them with the hand wheel bolts outside of bracket and spacers ins...

Page 14: ...ts stated on page 13 the operator is familiar with and able to comply with the requirements for safe operation listed on page 5 the fluid is one of the approved Martin fluids listed under Approved Fog...

Page 15: ...o be used to shut down the heater Settings are OFF shutdown heaters off STANDBY heaters remain on TIMER or CONTINUOUS mode Use the Menu Previous Next buttons to select the RUN MODE option Use the Up D...

Page 16: ...rightness Host Client linking priming factory reset and temperature control ZR45 only are found in the SETTINGS menu Use the Previous Next buttons to select the SETTINGS option Press the Enter button...

Page 17: ...UID OUT on the display to prevent damage to the pump s To suck the new fluid back into the machine and reset the FLUID OUT error replace refill the fluid reservoir and use the prime function Use the P...

Page 18: ...The factory settings are option setting FOG LEVEL 50 TIMER ON 10 seconds TIMER OFF 20 seconds RUN MODE STANDBY DMX 001 BACK LIGHT NORM LINK MODE RECEIVE1C PRIME NO TEMPERATURE NORM ZR45 Only...

Page 19: ...to this state If the machine was set to CONTINUOUS it will revert to this state Connection The JEM ZR series machine provides 5 pin XLR connectors on the rear of the machine for DMX connection For be...

Page 20: ...efore you can communicate with fixtures using RDM you must send a scan command also called a device discovery command to all the devices on the data link so that the RDM controller can identify them I...

Page 21: ...ATUS_MESSAGES DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL FACTORY_DEFAULTS DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION DEVICE_HOURS BOOT_SOFTWARE_VERSION_ID BOOT_SOFTWARE_VERSION_LABEL SL...

Page 22: ...is often preferred JEM Pro Fog Fluid Quick Dissipating offers a less dense effect compared to the benchmark JEM Pro Fog Fluid and is therefore less likely to interfere with video and film camera focu...

Page 23: ...uid RUSH Fog Fluid RUSH ELX Smoke Fluid Regular DJ Fluid DJ ZR45 Temperature Menu The different fluid types listed require correct selection of the relevant temperature setting in the TEMPERATURE sub...

Page 24: ...fect heat exchangers This advanced preventative maintenance fluid has been utilized by Martin service technicians for years of both cleaning and storing effect machines Utilizing Martin Pro Clean Stor...

Page 25: ...inside the unit which protects the supply to the pump DANGER Disconnect the power supply before removing any covers or changing fuses Live parts inside Rear panel fuse ZR25 120 V 10 A 250 V 230 V 6 3...

Page 26: ...on in DMX line Check DMX cables and connections LINK menu is set to SEND Set LINK menu to RECEIVE Fog output is weak Machine requires priming Use PRIME option to prime the machine page 17 Wet greasy n...

Page 27: ...e heater is at operating temperature and the unit is under DMX control FLUID OUT Run out of fluid Refill the fluid reservoir and operate the prime function in the SETTINGS menu CALIBRATION ERROR The m...

Page 28: ...189 ft per minute Fluid consumption max 100 ml per minute Maximum operating time maximum output 2 5 l of fluid 1 2 hours ZR35 Continuous effect output Ready time 9 minutes Coverage volume 800 m 28 25...

Page 29: ...lation Mounting Standing or hanging Clearance around machine 100 mm 4 in Orientation Up to 40 from horizontal Connections AC Power Neutrik PowerCON TRUE1 DMX Link mode in out 5 pin locking XLR Remote...

Page 30: ...ON TRUE1 molded NEMA 5 20P 2 m 6 6 ft P N 11501046 Accessories JEM ZR25 Ducting System with 5 m 16 4 ft ducting P N 92625012 JEM ZR35 Ducting System with 5 m 16 4 ft ducting P N 92625013 JEM ZR45 Duct...

Page 31: ...JEM ZR45 EU P N 92215360 Specifications subject to change without notice For the latest product specifications see www martin com Disposing of this product Martin products are supplied in compliance...

Page 32: ...www martin com...