34
Martin
®
Exterior Wash
TM
200 Series User Manual
Connections
Power input ......................................................................................... 1.8 m (5.9 ft.) open-ended cable tail
Power input cable type, EU models ...................................... H05RN-F, 300/500 V, 3 x 0.75 mm
2
, Ø 7 mm
Power input cable type, US models ............................................ SJOW, 300 V, 18 AWG, WL F1, Ø 8 mm
Data I/O ........................................................................... 1.8 m (5.9 ft.) open-ended 5-conductor cable tail
All cable entries ................................................................................................................. IP68 cable gland
Electrical
AC power .............................................................................................. 100-240/277 V nominal, 50/60 Hz
Power supply unit ............................................................................ Integrated, auto-sensing multi-voltage
Maximum total power consumption, Exterior Wash 200 and 220...................................................... 185 W
Maximum total power consumption, Exterior Wash 210 ................................................................... 165 W
Typical power consumption, steady state, all LEDs at zero intensity .................................................... 3 W
Typical half-cycle RMS inrush current at 240 V, 50 Hz ..................................................................... 10.3 A
Typical power and current
Exterior Wash 200
100 V, 60 Hz ........................................................................................................... 1.6 A, 160 W, PF 0.99
120 V, 60 Hz ........................................................................................................... 1.4 A, 160 W, PF 0.99
230 V, 50 Hz ........................................................................................................... 0.8 A, 160 W, PF 0.94
277 V, 60 Hz ........................................................................................................... 0.7 A, 160 W, PF 0.89
Exterior Wash 210
100 V, 60 Hz ........................................................................................................... 1.5 A, 148 W, PF 0.99
120 V, 60 Hz ........................................................................................................... 1.3 A, 146 W, PF 0.99
230 V, 50 Hz ........................................................................................................... 0.7 A, 146 W, PF 0.95
277 V, 60 Hz ........................................................................................................... 0.6 A, 146 W, PF 0.88
Exterior Wash 220
100 V, 60 Hz ........................................................................................................... 1.6 A, 162 W, PF 0.99
120 V, 60 Hz ........................................................................................................... 1.4 A, 160 W, PF 0.99
230 V, 50 Hz ........................................................................................................... 0.8 A, 160 W, PF 0.94
277 V, 60 Hz ........................................................................................................... 0.7 A, 160 W, PF 0.93
Measurements made with fixture in steady state at nominal voltage, ambient temperature (Ta) 20° C
(68° F), all LEDs at full intensity. Allow for a deviation of +/- 10%.
Thermal
Cooling ....................................................................................................................................... Convection
Maximum ambient temperature (Ta max.) ........................................................................... 45° C (113° F)
Minimum ambient temperature (Ta min.)* ............................................................................ -30° C (-22° F)
Maximum surface temperature, steady state, at 45° C ambient ........................................... 55° C (131° F)
Total heat dissipation (calculated, +/- 10%) ............................................................................ 640 BTU/hr.
*To ensure correct low temperature start-up, power must be maintained below -20° C (-4° F)
Approvals
Global CB Certification/IECEE ...................................................................... IEC 60598-2-5 (IEC 60598-1)
EU safety ................................................ EN60598-2-5 (EN60598-1), EN62471, EN62493, EN60598-2-1
EU EMC ............................... EN55015, EN61547, EN61000-3-2 & 3-3, EN61000-4-2, EN6100-4-4 & 4-5
US safety .............................................................................................................................. ANSI/UL 1598
US EMC ......................................................................................................... CFR Title 47 Part15 Class A
Canadian safety .......................................................................................................... CSA C.22.2 No. 250
Australia/NZ ........................................................................................................................................ RCM
Included Items
User manual
Control panel cover plate
Summary of Contents for Martin Exterior Wash 200 Series
Page 1: ...Exterior Wash 200 Series User manual...
Page 4: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ...www martin com...