Appendix A: NetLinx Control
N2312/N2322 User Manual
60
TABLE 27
NetLinx Configuration Options (Cont.)
Command
Description
System Number
Determines which system to connect. This setting is dependent upon the
Master Mode
selected (see above).
•
If
Master Mode
is set to
Auto
, the
System Number
is set and the system discovers the Central Controller’s IP
address.
•
If
Master Mode
is set to
Listen
, the device connects to any Central Controller.
•
If
Master Mode
is set to
URL
, the IP of the Central Controller is set.
Username
Username for the Central Controller.
Password
Password for the Central Controller.
Save
Save settings made on this page.
Batch Configurations Using N-Able
One of the many benefits of using N-Able control is batch configuration. This is especially useful in larger deployments. Instead of
using the individual unit web pages (discussed in the previous section), simply open N-Able and select
Tools > Batch Config
. See
FIG. 56
Selecting Batch Config in N-Able
The screen shown in
displays and allows you to choose the units you would like to enable for NetLinx control. To select
multiple units, hold down the
<Ctrl>
key. Once all of the units are selected, enable the
NetLinx On
button and click the
OK
button at
the bottom of the screen.
FIG. 57
Enabling NetLinx on Multiple Units
NOTE:
Items are not filtered. In other words, if you send a NetLinx command to a device that does not support it, the command is
simply ignored.