Encoder Configuration Options
N2312/N2322 User Manual
27
TABLE 2
Settings Page: Advanced Settings (Cont.)
Option
Description
Notes
Status Interval (secs)
Determine how often (in seconds) the unit transmits
status packets.
Serial Master Enable
Enable this device to be the server to the
designated client.
Serial Client Address
Enter the IP address of the serial client device.
IR Command Holdoff
Set the delay between IR command portions. The
default setting is 25 ms.
IR commands are sent in two parts. This setting is the
time (in milliseconds) between transmission of part
one and part two. The second part of the command is
inverted for confirmation purposes.
IR Repeat Holdoff
Set the repeat delay between IR commands. The default
setting is 90 ms.
This is the amount of time before a new command is
sent. For example, when pressing and holding the
volume button on a remote control, this is how long
until the command is repeated.
Save button
Click to save settings made in this portion of the
Advanced
section.
Enable SNMP
Enable to allow the device to handle Simple Network
Management Protocol (SNMP) queries.
Interleaved Multicast
Streams
Enables a multicast format which interleaves video and
audio streams.
In order for N-Series devices to communicate with
each other, their multicast settings must be
compatible.
Discovery Packet
Transmit
Enable the N-Series multicast discovery service (which
is used to identify units).
This is useful for larger network integrations when
broadcast packets will not cover the entire network.
Enabled by default.
Discovery Interval
(secs)
Determine how often (in seconds) the unit transmits
discovery packets.
KVM Enable
Enable to allow the ability to share mouse and keyboard
over the network. Disabled by default. When disabled,
the unit works like a non-KVM unit and ignores any
keyboard or mouse activity.
IR Passthrough Enable
Enables support for passing IR input data from one unit
to the IR output on another.
This must be enabled on both the sender and
receiver.
IR Client IP
Specifies the IP address of the unit to send IR
passthrough data to.
Netlinx Enable
Click to enable/disable NetLinx support on this device.
RS232 Settings
Set the baud rate, data bits, parity, and stop bit for the
RS232 serial interface.
Disable P1
Completely disables the P1 port for all traffic.
Once disabled, anything connected to the P1 port will
no longer be available on the network.
Save button
Click to save settings made in this portion of the
Advanced
section.