9.3.2 Performance data
Specifications of the electric motors used to power the electric Tensioner CT0 are the
following:
Tensioner CT0
Operating Tension (V)
Max current absorption (A)
24
15
Electrically operated, Tensioners have a load capacity proportional to the line speed.
9.3.3 Electric performance graph
Performance evaluated using the following system:
- two batteries 12V 230Ah connected in series;
- cable length 2m
- cable section 50mm²;
Load and speed measured at tensioner
0
20
40
60
80
100
120
140
160
0
5
10
15
20
25
30
35
40
45
50
55
L
Ine L
o
ad[
N]
Line speed [m/min]
Tensioner CT0 EL 24V
49 [m/min]
The max line load is limited
by the max current of the
motor
150 [N]
0
20
40
60
80
100
120
140
160
0
2
4
6
8
10
L
ine load
[
N]
Current [A]
Tensioner CT0 EL 24V
150 [N]
The max line load is
limited by the max current
of the motor