9.3.2 Electric unit wirings
NOTE!
Potentiometer range: from 1.5V to 9V; at 1.5V it outputs a 100% power; at 9V it
outputs a 0% power.
9.3.3 Electric unit equipment use
To have a maximum tensioning load of 12Kg, potentiometer has to be set at 6V.
Micro slide switch on line 2 for the reverse direction, to pull the rope out from Captive.
For the Fast-on connectors of 2 and 3 poles, provide also the counterpart and the pin to
connect.
For the mating connectors as table and figure below:
Connector
Mating
TE 180923
TE 180924
TE 180940
TE 180941
Molex 430200800
Molex 430250800