![Hardy LC300 Installation And Operating Instructions Manual Download Page 65](http://html1.mh-extra.com/html/hardy/lc300/lc300_installation-and-operating-instructions-manual_3911318065.webp)
HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 51
8-6
Automatic Water Fill Replacement Instructions
Step #
Operation Description
Visual Aids/Comments
1
If you are replacing the water fill solenoid then cut wires
to automatic water fill approx. 4" to 6" from rear of fill
solenoid as shown. Cut only if solenoid is to be
replaced.
2
Firmly pull solenoid up and away from switch post as
shown. If you are replacing the solenoid then discard.
Otherwise set the solenoid aside for later installation. If
you are not replacing the water fill valve then skip to
step # 8.
3
Using an adjustable wrench loosen and remove the flex
line fitting from solenoid assembly and set aside.
4
Using an adjustable wrench or other suitable tool
remove the automatic water fill assembly from heater.
Remove the brass elbow, 1/2"x1/4" bushing and 1/4"
close nipple from the assembly. These parts will be
reused on the new assembly.
5
Clean the screen inside the 1/2"x1/4" brass bushing
prior to re-installation using warm soapy water.
Cut wires
here
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.