HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 10
2-4
Set-Up of Grates (continued)
On the Hardy Model LC2500 first
open the firebox door and remove everything
from inside the
heater
except the air tube, two channel beams, the welded steel
baffle, and the 3/8” steel plate. Stand the two channel beams up on the edge with
flat side of channel over against the sides of the fire box.
Slide the 3/8” steel plate in the firebox across the air tube and channel beams
under the drop down section of the fire box against the back wall. Install the grates
across the air tube and the channel beams inline and end to end in front of the 3/8”
steel plate. Stand the steel flame baffle up with the 5” support legs on the bottom
facing the front of the heater. The openings should be facing and pushed against
the drop down section. The picture below shows the proper way for grates, flame
baffle and 3/8” steel plate to be installed. These grates are designed to be turned
over if they warp.