![Hardy LC300 Installation And Operating Instructions Manual Download Page 28](http://html1.mh-extra.com/html/hardy/lc300/lc300_installation-and-operating-instructions-manual_3911318028.webp)
HARDY MANUFACTURING CO., INC (MODEL LC300, LC500 & LC2500)
PAGE 14
2-7
Wiring Diagram (continued)
HEATER WIRING DIAGRAM
Model LC2500
GROUND
FAULT
CIRCUIT
INTERRUPTER
120
VOLT
NEUTRAL
CONNECTION
DIAGRAM
M1
RECIRCULATOR
4
6
R 3
BM
1
PM
SOL1
GFCI
L 1
L 2
SCHEMATIC
DIAGRAM
LEGEND
GFCI
GROUND FAULT CIRCUIT INTERRUPTER
R3
CIRCULATOR PUMP RELAY
PM
WATER CIRCULATOR PUMP
M1
RECIRCULATOR PUMP
T1
DAYTON AQUASTAT
BM1
DAMPER BLOWER MOTOR
SOL1
DAMPER SOLENOID
SOL2
WATER SOLENOID
F1
LOW WATER SWITCH
L1
LOW WATER LIGHT
R
F 1
L1
SOL2
1
2
3
4
5
6
7 8
R
BM
1
SOL1
R 3
PM
M1
RECIRCULATOR
ZONE
CIRCULATOR
SOL2
F 1
T1
Dayton
thermostat
R B
R
B