42
HardcalFailCounts 8
Insufficient number of counts between hard cal hi and hard cal lo
Status code FF
cmd in progress
C2 CAL CMD
Hex value: 0x66
Decimal value: 102
Write the hexadecimal value 0x66 to the command register to perform a C2 calibration.
Status Error code 1
Fail
Status Error code 2
ADC Failure
Status Error code 4
Motion
Status Error code 5
no C2 cells
Status Error code 6
C2 capacities not equal
Status Error code 7
Non-Hardy C2 load sensor
Status code FF
cmd in progress
IT Test
Hex value: 0x80
Decimal value: 128
Write the hexadecimal value 0x80 to the command register to perform an Integrated
Technician test. This test requires an IT summing card.
Status Error code 1
Fail or no IT Summing Card Found
Status code FF
cmd in progress
Stability Test
Hex value: 0x81
Decimal value: 129
Write the hexadecimal value 0x81 to the command register to perform the stability test.
Status Error code 1
Fail
Status code FF
cmd in progress