6.4.3 Making gas connections
1. Connect the restraining cable to the attachment point located at the rear of the rotisserie and to the wall using the
wall-mount bracket. The restraining cable and the wall mount bracket are supplied with the Quick-Disconnect kit
(the kit must be ordered along with the rotisserie). The wall mount bracket must be installed by a qualified
contractor.
2. The gas connection is located behind the right rear corner of the rotisserie (see
3. Apply an approved thread sealant to the threaded pipe end on the gas pipe extending from the rear of the
rotisserie.
4. Screw the quick-disconnect fitting (pipe adapter shown in
) onto the threaded connection.
5. Attach the flexible gas supply hose to the facility gas supply line and connect the gas to the rotisserie by sliding
the quick-disconnect hose fitting onto the pipe adapter.
6. Open the main gas valve from the facility gas supply line(s).
7. Check all hoses, fittings and connections for leaks prior to operating the rotisserie.
Figure 6-5: Gas Connection & Restraining Cable Locations
FAILURE TO CHECK FOR LEAKS MAY RESULT IN INJURY OR DEATH.
Restraining
Cable
Location
Gas Connection
Threaded Pipe End.