CLEAN THE AIR FILTER BOWLS
Clean the bowls on the Filter/regulator "O" and coalescing filter "P", Figure 2.15.
1. Power down the machine.
2. Turn the air supply to the machine OFF.
3. Lift the filter bowl sleeve and turn it counterclockwise about one eighth of a turn to release it
from the filter head. Do not use excessive force to remove a filter bowl.
4. Pour out contaminants that are present in the filter bowls.
5. Wipe the bowls clean with a lint-free cloth and change the filter if necessary.
6. Mount the bowl by aligning the bowl and sleeve on the head and turning it clockwise about one
eighth of a turn to tighten it in place. Pull down on the sleeve to confirm that the bowl is in place.
7. Grasp the sleeve and pull down to verify that the bowl is secure.
8. Turn the air supply to the machine ON.
9. Power up the machine.
10. Set filter/regulator "O", Figure 2.15, to 85 psi [5.9 bars] and check for air leaks. Correct any air
leaks as necessary.
11. Set the filter/regulator below 60 psi [4.2 bars] to test the pressure switch. The control will go into
an Emergency Stop condition.
12. Set the filter/regulator to an operating pressure between 70 psi to 90 psi [4.9 to 6.2 bars].
13. Press the Emergency Stop Reset push button.
14. Press the Reset key if it is still necessary to clear the alarm message from the control display.
15. Check the air system bowl for contamination, moisture, or air leaks. Correct any problems as
necessary.