AXIS DRIVE BATTERIES
Check the age of the drive unit batteries. Change the drive unit batteries, if necessary:
- CAUTION -
Fresh batteries must be installed at least once a year. Failure to perform this
maintenance will result in the loss of drive position information.
- NOTE -
The number of axis drive units to be checked will vary, depending on the machine
configuration.
Battery Pack Specifications
Hardinge Part Number:
18 -0011865-05
Voltage Rating:
6 volt
Battery Type:
Lithium
Use the following procedure to check or replace
the axis drive batteries.
1. Power down the machine.
2. Release six latches "D", Figure 2.3.
3. Open the left power case door.
4. Lift door release "F", Figure 2.4, and open the
right power case door.
- WARNING -
High voltage AC will be present in
the power case when the main cir-
cuit breaker switch is ON.
5. Move main circuit breaker switch "E", Figure
2.3, to the ON position.
M-507C
2-3
Figure 2.3 - Power Case Doors
D
TI5695
E
Figure 2.4 - Power Case Door Release
TP7939
F
Summary of Contents for T-42
Page 8: ... NOTES vi M 507C ...
Page 50: ... NOTES 1 42 M 507C ...
Page 84: ... NOTES 2 34 M 507C ...