13
HARDI
®
MUSTANG 3500 OPERATOR’S MANUAL
FIELD FLOW:
Displays the total gallons (liters) applied since the counter was last
reset to zero. If this counter is reset FIELD AREA will reset as well.
FOAM MARKER CONTROL
The area on the far right of the control panel, outlined with a yellow
border, is the Foam Marker Control area. This area is broken down into
three sections, each explained here:
LEFT/AUTO/RIGHT SWITCH:
Moving the switch to the left activates the LEFT foam marker. Moving
the switch to the right activates the RIGHT foam marker. Moving the
switch to the center position tells the controller to automatically
determine which marker will distribute foam. The middle AMBER
colored LED indicates marker is ON. The RED colored LED below the
dropper indicates which side is ON.
NOTE: If the
switch is in the center (AUTO) position on
start-up, the marker is set to start distributing
foam on the left side. When in AUTO marker
side changes automatically when the operator
transitions the master switch from AUTO to
HOLD or MAN to HOLD. Foam marker will NOT
turn on if the Master switch is in HOLD or if the
console is in rHold.
MARKER ON/OFF BUTTON:
To activate the Foam Marker in AUTO mode,
press the Marker On/Off button momentarily. To activate the foam
marker in Manual mode, press and hold the Marker On/Off switch
button for three seconds; when in Manual mode, the amber LED will
flash. In Manual mode, the Auto position of the Left/Auto/Right switch
turns the foam OFF.
FOAM ADJUST SWITCH:
When the Foam Marker Control is active, moving the switch to the left
decreases foam rate. Moving the switch to the right increases the foam
rate. When the foam switch is toggled, the lower right area of the
console display shows a percentage value between 0-100% indicating
the foam drop rate: 0%=min. 100%=max.