11
HARDI
®
MUSTANG 3500 OPERATOR’S MANUAL
LIGHT SENSOR
This sensor automatically turns the back lighting for the front panel on or
off as the lighting conditions dictate.
WARNING LIGHT
The console is equipped with a RED warning light. The light will
automatically turn on and flash when the actual application is plus or
minus 10 percent of the calibrated target rate. The RED warning light will
also be flashing when calibration mode is active on the console.
DISPLAY AREA
During normal operation, the console will display pressure in the lower
left corner of the display (if installed), application rate in the upper half of
the display and the selected rotary switch position data in the lower right
of the display. For example, in the figure below, the upper display tells the
operator that the actual target
RATE 1 is 20.0 GPA. The lower left
display tells the operator that their
pressure is at 56 PSI, and the
lower right display tells the
operator that their speed is
currently 5.8 MPH, if the rotary
switch is set to speed.
SYSTEM CAL BUTTON
To enter system calibration, toggle
the Master switch to HOLD and turn the rotary switch to SPEED, then
press and hold the SYSTEM CAL button and turn the power switch ON.
Release the SYSTEM CAL button when the console displays SYS.
Upon entering SYSTEM CAL, the display will read “SYS” and the
calibration indicator will be lit. Any changes to the factory-preset values
can be made while in SYSTEM CAL. Changes will take effect as soon as
SYSTEM CAL is exited. To exit SYSTEM CAL, press the SYSTEM CAL
button. See Calibration section for more information.