50
GB 14 07 03
3. Set the blower at max. speed.
4. Check the feed and working pressure:
Feed pressure, P2
15-20 bar (218-290
p.s.i.)
Working pressure, P1, approx.
18 m
180 bar (2610 p.s.i.)
20 m
190 bar (2755 p.s.i.)
21 m
200 bar (2900 p.s.i.)
24 m
240 bar (3045 p.s.i.)
Adjust feed pressure if necessary.
Failure to reach feed and working pressure indicates
that the transmission needs overhauling.
Nozzle tubes and f
Nozzle tubes and f
Nozzle tubes and f
Nozzle tubes and f
Nozzle tubes and fittings
ittings
ittings
ittings
ittings
Poor seals are usually caused by:
• missing O-rings or gaskets
• damaged or incorrectly seated O-rings
• dry or deformed O-rings or gaskets
• foreign bodies.
Therefore, in case of leaks:
DO NOT overtigthen, disassem-
ble, check condition and position
of O-ring or gasket, clean,
lubricate and reassemble.
For radial connections only hand tighten them.
The O-rings must always be greased all the way round
before refitting.
For face connections, a little mechanical leverage may
be used.
T199-0001
T199-0001
Adjustment of head lamps
Adjustment of head lamps
Adjustment of head lamps
Adjustment of head lamps
Adjustment of head lamps
Adjust the head lamps the following way:
1. Position the sprayer facing a wall or screen with a
distance between wall and head lamps of 2 metres.
2. Mark a point on the wall or screen by sighting down
the hood centre line.
3. Draw a vertical line
1
through the point.
4. Measure the head lamp height, and draw a horizontal
line
2
through the vertical line
1
at head lamp height
4
.
5. Measure the distance between centre of
RH and LH head lamp. Mark two
points
3
on the horizontal line
with head lamp distance,
placed with equal
distance from
the
vertical
line
1
.
6. Switch on
the main
beam,
and
cover off
LH head
lamp.
7. Adjust
RH head
lamp so
the point
3
is in the
centre of
the beam.
8. Cover RH head lamp and repeat point 7 on LH head
lamp.
Adjustment of
Adjustment of
Adjustment of
Adjustment of
Adjustment of 3-w
3-w
3-w
3-w
3-wa
aa
a
ay-v
y-v
y-v
y-v
y-valv
alv
alv
alv
alve
ee
e
e
The MANIFOLD valve can
be adjusted if it is too tight
to operate - or if it is too
loose (= liquid leakage).
Use a suitable tool and
adjust the toothed ring
inside the valve as shown
on the drawing.
T109-0001
T090-0006
Summary of Contents for MARRO TWIN FORCE 1000