29
Routine Maintenance
Table 1 provides a basic guide to routine maintenance requirements for the various
components of the Jetter.
Warning:
Maintenance should only be carried out with the engine turned off and when cold.
5.1. Maintenance Procedures
Prior to use / Daily /
After 8 hours running
Check inlet water filter element (Ref Para 5.2)
Check engine oil level on dip stick (Ref section 9)
Check engine coolant level (Ref section 9)
Visual check for hose damage/water leaks & for any
cracks in frame/chassis etc.
Check ignition and warning lamp operation
Check all lugnuts on bolts tires and torque to 90 lbs/ft
Weekly / every 24
hours running
Visually inspect Jetter for security checking for any
loose, damaged, or missing parts.
Check air filter cleanliness (Ref section 9)
Check engine fuel water trap for contamination (Ref
section 9)
3 months / 50 hours
First service contact Harben Inc.
6 months / 150 hours
Inspect tanks and fittings for leaks, thoroughly clean &
flush through (with hot water more than 158°F)
Tighten any loose joints
Grease the hydraulic hose reel bearing blocks
Check condition of 12volt start battery
Grease battery terminals for protection
Check alternator belt
Yearly / 300 hours
Intermediate service of engine, gearbox and pump
required (Contact Harben Inc.)
Closely inspect the structural integrity of the framework
for signs of stress and cracking
Check hydraulic filter gauge. If it reads in the red replace
the filter and oil (Shell Tellus 22)
Carry out detailed inspection of pipes, hoses, and
fittings.
Dismantle, clean & lube the hydraulic diverter valve
2 yearly / 600 hours
Major service of engine, gearbox and pump required
(Contact Harben Inc.)
Replace the pump inlet/delivery valves and diaphragms
Check wiring terminals/connections and continuity of
electrical earth.
Table 1 Recommended Routine Maintenance
For a detailed guide to pump maintenance and overhaul procedures refer to Section 7.
For routing engine maintenance please refer to the engine handbook supplied with the unit.
Summary of Contents for E Series
Page 10: ...8 Fig 2 1 E180 Remote Primary Components ...
Page 11: ...9 Fig 2 2 E180 Manual Primary Components ...
Page 12: ...10 Fig 2 3 E Series Remote Primary Components ...
Page 13: ...11 Fig 2 4 E Series Manual Primary Components ...
Page 14: ...12 Fig 2 5 ET180 Remote Primary Components ...
Page 15: ...13 Fig 2 6 ET180 Manual Primary Components ...
Page 35: ...33 Burst disc holder showing White burst disc ...
Page 41: ...39 Pump Refer to the P Type Service Manual Part No 061 352 included with your Jetter ...
Page 73: ...71 Service Documents 11 1 Service Checklist ...
Page 74: ...72 11 2 Service Logbook ...