Flowplant Century Pump Manual
ix.
Continue replacing the Barrels in an alphabetical and clockwise order.
x.
Place Retaining Ring (28) over Bearing and Slippers. Fit Circlip (54) into Bearing
groove.
xi.
Screw retaining Screw (95), with Bonded Seal (64), through Crankcase into the Barrel,
leaving about one turn loose.
xii.
Clean and check '0' ring (70) before placing it in greased groove of Delivery Crankcase
(3).
xiii.
Slide the Sleeve (7) over the Shaft (17), and place the Disc Springs (59) over the
Sleeve so that they rest on the Eccentric (6).
xiv.
Apply a small amount of retaining compound to the threads of the Shaft Bolt (92) and
screw the Shaft Bolt, with Washer (88), into the end of the Shaft (17). Torque the
Shaft Bolt to that specified in
4.2.3.
xv.
Turn the pump to the vertical position. Place Bolts (99) through the Delivery
Crankcase, and slide the Spacer Assemblies (112) over them.
xvi.
Grease '0' rings (71) and the Barrel bore of the Inlet Crankcase (2).
xvii.
Place the Inlet Crankcase (2) in its correct position over the Shaft and Barrels (the oil
filler should be at the top between Barrels 'A' and 'H').
xviii.
Push the Inlet Crankcase (2) over the Barrels until the threads of Bolts (99) engage.
xix.
Tighten Bolts (99) until the Crankcase halves are completely together. Care should be
taken to tighten diagonally and a little at a time.
xx.
Fully tighten Screw (95).
xxi.
Fit Bearing Retainer (9) and '0' ring (71) using Nut (86) with Washers (103).
xxii.
Place the Bleed Rings (44) and Bleed Screws (93) over the Barrels.
Note: If internal parts of the Barrels or Valves were removed, refer to the appropriate
procedure and ensure they are re-assembled correctly.
xxiii.
Fit Key (30) into the cleaned Shaft keyway.
xxiv.
Clean the bore of Counter Balance (4) and Coupling (5). Check that both
slide over
the Shaft, but do not assemble.
xxv.
Fit Bell Housing (84) using Nuts (86) with Washers (103).
xxvi.
Grease the Shaft and the bores of the Counter Balance and Coupling.
63
Summary of Contents for CENTURY
Page 14: ...Section 1 Pump Technical Data 11 ...
Page 25: ...Section 2 Pump Installation 22 ...
Page 32: ...Section 3 General Operating Information 29 ...
Page 47: ...Section 4 Pump Maintenance and Overhaul Procedures 44 ...
Page 68: ...Fig 4 4 Century pump Assembly 65 ...
Page 69: ...66 ...
Page 77: ...Section 5 Warranty 74 ...