background image

 

 

Unless a dress guard is fitted, this appliance shall be installed with a hearth that projects at 
least 300 mm in front of the naked flame/incandescent fuel bed, extends at least 150 mm at 
either side, and around its periphery is a height of at least 50 mm above finished floor level. 

11.  Lead  the  hose  away  from  the  built-in  gas  fire  burner  kit  without  twisting  it.  Do  not  let  the 

hose touch the hot surface. 

12.  Never change the air valve settings of the burner. 
13.  Every time the gas connection is reconnected do a leak test. 
14.  Those parts sealed by the manufacturer or the agent must not be altered by the user. 
15.  Any modification of this built-in gas fire burner kit may be dangerous. 
16.  Do not move this built-in gas fire burner kit during use. 
17.  Turn off the gas supply at the cylinder or main shut off valve of city network gas after use. 
18.  Do not touch the logs or lava rocks until they cool down. 
19.  This appliance is intended for warming purposes. 
20.  This  appliance  has  a  naked  flame,  a  suitable  guard  should  be  used  for  the  protection  of 

young children,  the elderly and the infirm. IT DOES NOT GIVE FULL PROTECTION FOR 
YOUNG  CHILDREN  OR  THE  INFIRM.  It  is  advisable  to fit  the  dress  guard available  from 
the same dealer or qualified installer. Failure to fit this dress guard will result in a potential 
hazard  to  clothing  when  approaching  the  appliance.  The  dress  guard  is  not  supplied  with 
the  appliance,  the  installer  shall  inform  the  user  of  the  local  rules  in  force  and  advise  the 
fitting of the same dealer

’s or qualified installer’s dress guard. He shall also warn the user of 

the  hazard  caused  to  clothing  by  open  flames  if  the  dress  guard  is  not  fitted. 

Recommendation:

  for  any  additional  guard  that  may  be  required  for  the  protection  of 

young  children,  aged  or  infirm  persons.  The  minimum  distance  should  be  10mm  between 
the appliance to any ventilation grille. 

21. 

When  first  use,  preheat  the  lava  rocks  and  logs  for  15  minutes  to  burn  out  the impurities 
and air in the natural lava rocks and handmade logs.

 

22. 

To  change  the  gas  cylinder  in  an  amply  ventilated  area,  away  from  any  ignition  source 
(candle, cigarettes, other flame producing appliances).

 

23. 

This appliance must be installed and the gas cylinder stored in accordance with the national 
regulations in force.

 

24. 

Shut off the valve at the gas cylinder or the regulator before moving the appliance.

 

25. 

Use only the type of gas and the type of cylinder specified by the manufacturer.

 

 

13B

Contents 

 

14B

1.

 

Technical Data

 

15B

Page 3-3

 

16B

2. Instructions for assembly

 

17B

Page 4-14

 

18B

3. Installation and operation instructions 

 

19B

Page 15-19

 

20B

4. Maintenance

 

21B

Page 20-21

 

 

The  built-in  gas  fire  burner  kit  is  an  I3+(28-30/37),  I3  B/P(30),  I3  B/P(50),  I2L(G25)  & 
I2H/I2E/I2E+(G20)  appliance,  designed  to  operate  on  Butane  at  28/30mbar,  Propane  37mbar, 
B/P  30/50mbar,  I2L  at  25mbar  &  I2H/I2E/I2E+  at  20mbar.  Gas  consumption,  pressures  and 
injectors orifices sizes are shown below: 

 

Summary of Contents for 4001BIS/I2 Plus

Page 1: ...r their mixture at 30mbar Injector SR2201BI I2 SRR2201BI I2 1 2 mm SR4001BIS I2 SR4001BIR I2 1 65mm AT DE SK CH Cat I3 B P 50 Butane propane or their mixture at 50mbar Injector SR2201BI I2 SRR2201BI I...

Page 2: ...r kit unattended while using 6 In the event of a gas leak the appliance shall not be used or if alight turn off gas supply at the LPG cylinder or the nearest main shut off valve of city network gas An...

Page 3: ...ce The dress guard is not supplied with the appliance the installer shall inform the user of the local rules in force and advise the fitting of the same dealer s or qualified installer s dress guard H...

Page 4: ...I2E I2E 3 0mm 13 kW 946 g h The marking on the injector for example 1 20 indicates that the size of injector is 1 20mm LP Gas Regulator A gas regulator confirming to the national standard must be fit...

Page 5: ...Igniter 1 29 Plate Control panel 1 09 Burner head 1 30 Bracket Burner Bowl 1 10 Leakage Protector 1 31 Frame 1 11 Windpipe 1 32 Screw M4F07 4 12 Nut Pilot Igniter 1 33 Nut M4 4 13 Washer 1 34 Screw M...

Page 6: ...iter 1 29 Plate Control panel 1 09 Burner head 1 30 Bracket Burner Bowl 1 10 Leakage Protector 1 31 Frame 1 11 Windpipe 1 32 Screw M4F07 4 12 Nut Pilot Igniter 1 33 Nut M4 4 13 Washer 1 34 Screw M6F41...

Page 7: ...6 SR2201BI I2 SR4001BIS I2 series exploded...

Page 8: ...7 SRR2201BI I2 SR4001BIR I2 series exploded...

Page 9: ...d inlet fitting as shown in FIG 01 FIG 02 below SR2201BII2 SRR2201BII2 SR4001BISI2 SR4001BIRI2 Attach the hose to the manifold inlet fitting with a national standard NG connector and secure the hose t...

Page 10: ...rner kit onto the opening of your wooden table as shown in FIG 01 NOTE You may need to use and attach the optional table support bracket kit as shown in FIG 02 to secure the slats you saw off Adjust a...

Page 11: ...perpendicular to the igniter box Lay the other logs in a teepee configuration over the first log It is important that the logs not lay directly on top of the burner By blocking the burner it will imp...

Page 12: ...11 SR4001BIS I2 SR4001BIR I2...

Page 13: ...e ground with screw Attach the manifold inlet fitting with the national standard NG connector supplied Connection of the NG supply to the appliance inlet should be made by a qualified installer Note F...

Page 14: ...NSTRUCTIONS 74BUINSTALLATION OF THE LID When the appliance is not in use disconnect and take off the logs and close the lid to use as a normal table NOTE Be sure unit is cool before touching any of th...

Page 15: ...ES Turn off the gas supply at the cylinder or main shut off valve of city network gas Do not try to light any appliance Do not touch any electrical switches Do not use any phone including cellular pho...

Page 16: ...e area clear and free from combustible materials gasoline and other flammable vapors and liquids Installation and repair should be done by a qualified service person The appliance should be inspected...

Page 17: ...regulator for details regarding fitting 3 Test for gas leaks Do a leak test each time the cylinder is installed whether or not it has been filled Check all other joints at least once a year lf the hos...

Page 18: ...areas where the hose may be subjected to accidental damage 7 Open tank valve fully Turn the on off valve at the unit to the off position to pressurize the hose assembly Use a soapy water solution to...

Page 19: ...y part has been under water Immediately call a qualified service technician to water WHAT TO DO IF YOU SMELL GAS Turn off the gas supply at the cylinder or main shut off valve of city network gas Do n...

Page 20: ...s to ensure it is not cracked or damaged in any way INSPECTION AFTER REPAIR Any repairs must be performed by a qualified installer service agency or your gas provider 1 Check all the joints 2 Smell al...

Reviews: