If the 4 kg drop tube is fitted with two PipeFeeder HighSpeeds, make sure that they do not 
run for longer than a combined total of 10 seconds. 

 

 

Important!   

 

• 

The Dump in only intended for cylindrical concentrate with a diameter 
of Ø4 to Ø6 mm. The manufacturer cannot guarantee proper functio-
ning for other shapes or dimensions.

 

• 

During the installation of the Dump ensure the pressure of the concen-
trate on the dosing unit is greater than 50 kg.

 

• 

Never insert your hand into the bottom of the Dump when it is still in 
operation or is connected to the electrical power supply (pic. 5). The 
size of the exit point is limited by a bar to prevent cuts.

 

 

Maintenance

 

1.

 

Check the Dump installation daily for faults and wear. Do this by means of a control 
test on the feed motors. Make sure that the vibrations and noise caused by the Dump 
are reduced as much as possible.

 

2.

 

If the Dump needs maintenance and is connected to the controls ensure that the 
Duump cannot start unexpectedly. Make sure there is no voltage on the installation! 
To do this plug the power supply off at the control unit of the dosing motor.

 

3.

 

It is recommended to have repairs and maintenance carried out by a specialist.

 

4. 

 

To avoid electric shocks or getting trapped in the feed auger never open the houssing 
when the Dump is still running.

 

5.

 

For the safety of all concerned the user/owner of the Dump should follow the advice 
and directions given in the installation instructions. If it is not possible to follow this it 
is the responsibility of the user and the manufacturer cannot be held responsible/
liable for any injury or damage to or by the product.

 

 

Please note! In case of maintenance or disassembly make sure to always first 
switch off the electricity of the installation.

 

 

Cleaning

 

Clean the Dump regularly with a moist cloth. Do not spray water under the hood in the 
stock pipe. To guarantee the equipment functions correctly make sure the exit point is 
clean an stays clean.

 

 

Please note! Do not spray with high pressure in or on the Dump. This can cause 
blockage.

 

 

Disassembly

 

In case of disassembly all parts must be separated by material type for processing through 
a suitable waste management system.

 

 

Summary of Contents for PipeFeeder Dump

Page 1: ...tion of Original Instruction for use According to Annex 1 Chapter 1 7 4 Machine guideline 2006 42 EG Doetinchem The Netherlands www hanskamp nl en Carrousel voersysteem Carousel feeding system Karusse...

Page 2: ...een compiled with care Hanskamp shall not be liable for errors or faults in this manual The recommendations are meant to serve as guidelines All instructions pictures and specifications in this manual...

Page 3: ...ousel The benefit Faster milking with signifi cantly less concentrate Hanskamp s Dump is supplied with 1 limit switch as standard The switch enables the Dump to release the feed at exactly the right t...

Page 4: ...YOU are responsible for the SAFE operation and maintenance of your Dump YOU must make sure that you and anyone else who is going to operate maintain or work in the vi cinity of the Dump knows all the...

Page 5: ...ctrician must install the electrical power supply fr the Dump Make sure the electrical grounding of the electrical system and all parts of the Dump meet the local rules and regulations Replace any dam...

Page 6: ...aintain the Dump Switch off the electrical power supply by taking the plug out of the power point and secure the plug before you clean or do maintenance on the Dump Wear protective clothing and safety...

Page 7: ...ipped the boxes will be transported on a pallet This pallet is completely sealed and the corners are covered with tape to prevent damage The Dump is also stored this way Please note Always use an appr...

Page 8: ...Place the sticker on the surface and press a small portion of the self adhesive layer onto the surface Carefully remove the foil and press down the rest of the sticker Remove any air bubbles with a n...

Page 9: ...ling Art no 011 145 000 to the cross tube ensuring that the dump valve remains horizontal The cams at the end of the cross tube fit into the slots in the motor plate preventing the motor from turning...

Page 10: ...ll a drop tube of at least 85 cm or shield off the cutting hazard in another way 7 Mount the Dump to a wall or a frame with the PipeFeeder clamps Art no 001 902 000 For safety reasons ensure that the...

Page 11: ...mp in such a way that both up per sides of the tubes are even 12 Fix the PVC tube with 4 screws 13 Slide in the storage container into the PVC tube that has just been mounted Art No 002 055 000 14 To...

Page 12: ...rough at once If you do not have 24V AC DC available order the Hanskamp PowerU nit 24VDC 10A with power boost Art no 002 812 000 Danger When connected to the power supply the valve of the Dump will st...

Page 13: ...onnected to the controls ensure that the Duump cannot start unexpectedly Make sure there is no voltage on the installation To do this plug the power supply off at the control unit of the dosing motor...

Page 14: ...List of included amendments in these installation and operating instructions Copyright and disclaimer The information given in this publication is provided for information purposes only and does not...

Page 15: ...the declaration relates fully complies with the provisions of the following direc tive s Machine Directive 2006 42 EG EMC Directive And completely or partially meets the following essential requireme...

Page 16: ...er Take of the cover at the motor and check the indicator lights on the PCB Check supply and control voltage Check if the rotor spins Connection piece between the motor and valve could be broken Remov...

Page 17: ...voersysteem Carousel feeding system Karussel F tterungssystem Syst me d alimentation carrousel Loose components It is possible to reorder loose components from your supplier for maintenance or for any...

Page 18: ...le 1 011 152 000 Stainless steel Pipe 129x2 for Dump Kg complete 1 011 155 000 Dosingvalve complete Stainless steel for Dump 1 011 158 000 Slide bearing nylon black 10x12x21mm for Dump 2 011 159 000 S...

Page 19: ...roTech B V the Netherlands www hanskamp nl en Dump EN Carrousel voersysteem Carousel feeding system Karussel F tterungssystem Syst me d alimentation carrousel Individual parts of PipeFeeder Dump Conta...

Page 20: ...0 Chipboardscrew 4 x 13mm stainless steel 2 002 055 000 Storage container white 28 liter 17 kg 1 011 145 004 RIM motor complete 28RPM 4kg for PF Dump 1 011 150 000 Limit switch No with flexible rod co...

Page 21: ...herlands www hanskamp nl en Dump EN Carrousel voersysteem Carousel feeding system Karussel F tterungssystem Syst me d alimentation carrousel Installation dimensions 1Kg Version extra short 724 5mm sho...

Page 22: ...ds www hanskamp nl en Dump EN Carrousel voersysteem Carousel feeding system Karussel F tterungssystem Syst me d alimentation carrousel Installation dimensions 4Kg version Visit us on Extra short 724 5...

Page 23: ...mp nl en Dump EN Carrousel voersysteem Carousel feeding system Karussel F tterungssystem Syst me d alimentation carrousel Hanskamp AgroTech B V Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel 31...

Reviews: