12
-
23
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
Dump
EN
Carrousel voersysteem—Carousel feeding system—Karussel
-
Fütterungssystem—Système d
’
alimentation carrousel
Electrical connection:
The dump is powered by 24V AC/DC and is activated by a limit switch (Art. no.: 011
-
150
-
000). The limit switch must be positioned so that it switches as soon as the feed trough
moves under the drop tube. The entire supply in the drop tube will be released into the
feed trough at once. If you do not have 24V AC/DC available, order the Hanskamp PowerU-
nit 24VDC 10A with power boost (Art. no.: 002
-
812
-
000).
Danger! When connected to the power supply, the valve of the Dump will
start to rotate as soon as the limit switch is actuated.
Caution! When using a 4 kg drop tube with a single PipeFeeder HighSpeed,
make sure that the PipeFeeder does not run for longer than 10 seconds. If it
runs for longer, the drop tube will overflow, causing blockage and preventing
the valve from operating.
11
Brown
Green
Yellow
Limit switch NO/NC
With Dump
Connect
NO 13/14
Yellow (NC) not used
Green (NO)
RIM motor complete
Brown
White
Yellow
Green
Pink
Grey
Green
Red