background image

2

K129e 
JAN 2014

NAMEPLATE INFORMATION

The nameplate, located on the side of Hansen EZ-SRV™ 

cartridge pressure-relief valves, contains important 

information about the valve pressure setting, capacity 
and date of manufacture. The date code traces the 
month and year the valve was built. Example: A valve 
with Serial No. 06B 10, indicates that it was built in June 

of 2010. See nameplate below for location of data and 
photo of EZ-SRV replacement cartridge.

1.  CATALOG NUMBER

2. AIR CAPACITY OR LIQUID FLOW RATE 

ACCORDING TO THE SET PRESSURE

3. SET PRESSURE

4.  INLET SIZE

5.  MONTH AND DAY OF MANUFACTURE AND 

VALVE NUMBER

6. YEAR OF MANUFACTURE AND CURRENT 

REVISION LETTER

1

2

4

6

5

3

APPLICATIONS

Hansen EZ-SRV™ cartridge pressure-relief valves 
typically are installed on pressure vessels to protect 
from overpressure. Several design codes for refrigeration 
systems require that pressure vessels have protection 
from excessive pressure. For example, Hansen cartridge 
pressure-relief valves comply with the requirements 
of ANSI/ASHRAE Standard 15 Safety Standard for 
Refrigeration Systems, and ANSI/IIAR 2 Equipment, 
Design, and Installation of Closed-Circuit Ammonia 
Mechanical Refrigerating Systems. Once installed, 
a properly selected Hansen EZ-SRV™ car tridge 
pressure-relief valve will vent to atmosphere excessive 
overpressure. After discharge, these valves will quickly 
reseat to minimize loss of refrigerant. After discharge, 
relief valves must be replaced as soon as possible 
because debris may have settled on the seat, allowing 
the seat to leak out refrigerant. Hansen EZ-SRV™ valves 
must be installed in the vapor space above the liquid 
level of any vessel or component which contains liquid 
and vapor. (Hansen offers the EZLQ, a liquid relief valve 
for use with ASME rated pressure vessels and is rated 
U.S. GPM.)

MATERIAL SPECIFICATIONS

EZ-Fitting Body:  ASME SA105 steel
EZ-SRV™ Cartridge:  ASME SA395, ductile iron
Internal Seating Components:  stainless steel
Piston:  stainless steel
Seat O-rings:  neoprene
Spring:  stainless steel
Maximum Temperature Rating:  240°F (115°C) 
Safe Working Pressure:  600 psig (41 bar)
Setting Range: 

  Gas Service: 150 to 600 psig (10.4 to 41 bar)
  Liquid Service: 50 to 100 psid (3.4 to 6.9 bar)

Reseat Pressure (blowdown): 

  Gas Service: within 15% below set point
  Liquid Service: within 20% below set point

CODE AND STANDARD COMPLIANCE

ASME Boiler and Pressure Vessel Code, Section VIII, 

Division 1

ANSI/ASHRAE Standard 15 Safety Standard for 

Refrigeration Systems

ANSI/IIAR 2 Equipment, Design, and Installation of 

Closed-Circuit Ammonia Mechanical Refrigerating 
Systems

ISO 4126, Safety Devices for Protection of Excessive 

Pressure

PED (Pressure Equipment Directive) Category IV

EZ-SRV Replacement Cartridge

Summary of Contents for EZ-SRV Series

Page 1: ...ery five years However if a relief valve has discharged it must be replaced as soon as possible Valve replacement with the Hansen EZ SRV is fast and easy saving significant time and expense compared t...

Page 2: ...ssure relief valve will vent to atmosphere excessive overpressure After discharge these valves will quickly reseat to minimize loss of refrigerant After discharge relief valves must be replaced as soo...

Page 3: ...ies section of this bulletin Example To determine the minimum required capacity of a relief valve for a vessel containing ammonia that measures 16 feet 4 9 m in length and 6 feet 1 8 m in outside diam...

Page 4: ...ront port is closed or backseated back port is closed the backseated position is recommended because it takes pressure off the packing and reduces the possibility of packing leaks Vent the relief valv...

Page 5: ...Air Capacity Pressure Size Set I n l e t Cat No O u t l e t HANSEN TECHNOLOGIES U S A CORPORATION EZ FITTING CONNECTIONS DN BT1 BW1 1 2 x 3 4 15 x 20 BT2 BW2 3 4 x 1 20 x 25 BT4 BW4 1 x 1 1 4 25 x 32...

Page 6: ...te on pressure differential Set points are low differentials of 50 75 and 100 psid The equipment the liquid relief valve is protecting must be designed for a pressure greater than the sum of the desig...

Page 7: ...re use with plated coupling EZ SRV shown with Three Way Shut off Valve and optional Rupture Discs Gauge Valves and Pressure Gauges THREE WAY DUAL SHUT OFF VALVES SHOWN BACKSEATED OUTLET OPEN OUTLET CL...

Page 8: ...tory May require extra delivery time To Order Specify Catalog Number Pressure Setting Optional H7771 Gauge Valve and HG27 Pressure Gauge EZ Adapter if needed and accessories EZ Adapter p n 40 0331 EZ...