background image

15

APP-001b

APR 2007

PARTS LIST

MECHANICAL

HLLSW

Float Switch Assembly

20-1772

Water Bubbler Assembly, antisyphon (w/end connections)

20-1186

Metering Valve

20-1198

Metering Valve Seal Kit

20-1648

Metering Valve Strainer

20-1737

Screen Assembly Replacement Kit for above strainer, includes:

20-1535 Screen Assembly

78-0016 Strainer Cap Gasket

ST050

Water Purge Line Strainer

78-1001

Screen Assembly Replacement Kit for above strainer, includes:

78-0005 Screen Assembly
78-0016 Strainer Cap Gasket

70-1059

Plunger Kit for all purger solenoid valves

20-1183

Check Valve, 1 psid (.07 bar) with orifice

20-2489

Check Valve, 1 psid (.07 bar) no orifice

20-1185

Check Valve, 225 psid (15.5 bar)

20-1214

Check Valve Seal Kit for 1 psid and 225 psid check valves

20-1311

Liquid Drainer

20-2432

Vapor Trap

H5600R

Relief Valve, 300 psi

ELECTRICAL

70-1088

Solenoid Coil, DIN plug - 115V, 50/60 Hz, 16 Watt

20-2428

Electric Heater, 115V, 50/60 Hz, 750 Watt

20-2477

Electric Heater, 230V, 50/60 Hz, 750 Watt

20-1279

Fuse, 2 amp, 115V purger

20-2402

Fuse, 15 amp, 115V purger

20-1695

Fuse, 3 amp, 220V purger

20-2463

Fuse, 8 amp, 220V purger

20-2403

PLC, 12 position

20-2416

PLC, 6 position

20-2405

PLC module, thermocouple input

20-2406

PLC module, current input

20-2407

PLC module, AC output

20-2408

PLC module, AC input/output

20-2409

PLC control console

20-2410

Heater Contactor

20-2411

Cable, PLC to Control Console

PSU

100-240VAC:24VDC Power Supply

HPT717

Water Concentration Sensor

SPSN-1

Liquid Make-up Level Sensor

SPSN-1

Low Liquid Level Sensor

20-2429

Plate Heater Temperature Sensor

20-2430

Liquid Temperature Sensor

20-2431

Evaporator Shell Temperature Sensor

75-3002

Pressure Transducer

20-2404

PLC module, AC input

20-2413

PLC module, DC input/relay output

20-2464

Transformer 220/115V

Summary of Contents for APP08

Page 1: ...RGER Plus is a totally automatic electronically controlled refrigerant noncondensible gas air and water purger for reducing the energy costs of operating an ammonia refrigeration system All models are...

Page 2: ...circumstances only one point is effectively purged The best practice is to purge each condenser and receiver circuit separately It is extremely important to install purge points at locations sure to b...

Page 3: ...some cases a small high pressure auxiliary receiver is located at the outlet of one or more condensers This receiver should have a purge point at the top Where a high pressure float regulator is used...

Page 4: ...ected into the purger The low pressure pumped liquid line feeds makeup liquid as required during purging The line contains liquid ammonia that typically is also contaminated with water which is to be...

Page 5: ...mps electrical supply on a 15 amp circuit breaker are available All models have a 13 mm knockout on the side of the control cabinet to access the power connection terminal strip Any unused knockout ho...

Page 6: ...connecting shut off valves are open See Figure 4 START UP Make sure all piping electrical connections and settings are complete as described in this bulletin Open the foul gas low pressure pumped liq...

Page 7: ...there are no releases to atmosphere 1 WATER BUBBLER WATER BUBBLER OVERFLOW TUBE FOUL GAS LINE LOW PRESSURE PUMPED LIQUID LINE SUCTION LINE FILL LINE D B C FLOW REGULATOR GAUGE VALVE GAUGE VALVE LIQUI...

Page 8: ...system parameters The operator can switch between the two message types by pressing the esc key Control Console Specifications Display Type Character LCD 4 lines by 20 characters w LED backlight Encl...

Page 9: ...and the temperature of the plate heaters see figure 4 Another press of this key displays the pressures in the low side and the high side of the purger A final press of this key returns the display to...

Page 10: ...follows air purge limit 60 minute limit normal 0 60 min startup 1 nolimit purge point enable 01 1 enable 0 skip 02 1 enable 0 skip 03 1 enable 0 skip 04 1 enable 0 skip 05 1 enable 0 skip 06 1 enable...

Page 11: ...normal 7777 loss of lp liq will appear when the liquid make up solenoid valve has been energized for 30 minutes continuously ERROR HEATER FAULT will be displayed if the heaters are on longer than 4 ho...

Page 12: ...1 psid 07 bar check valve in the water purge line to prevent reverse flow of water into the purger from the customer supplied container The water bubbler fill line has a check valve OPERATION OF PURG...

Page 13: ...URGE GAS GAUGE VALVE WIDE OPEN DURING OPERATION CLOSED FOR SERVICING PURGER PURGE GAS 1 32 0 8 MM DIA METERING ORIFICE 0 07 BAR PURGE GAS TO WATER BUBBLER OR TO CUSTOMER SUPPLIED WATER BOTTLE CHECK VA...

Page 14: ...r fill line valve The purger will pump down in several hours To accelerate the process attach ammonia hoses to the oil drain valves and pump out into a suction line Close the low pressure liquid retur...

Page 15: ...por Trap H5600R Relief Valve 300 psi ELECTRICAL 70 1088 Solenoid Coil DIN plug 115V 50 60 Hz 16 Watt 20 2428 Electric Heater 115V 50 60 Hz 750 Watt 20 2477 Electric Heater 230V 50 60 Hz 750 Watt 20 12...

Page 16: ...ctional pushbutton several times until the pressures are displayed Verify that the high side pressure is greater than 80 psig 5 5 barg Action If the high side pressure displayed is less than 80 psig 5...

Page 17: ...id line plugged strainers or the plastic shipping cap still in the liquid line flange Action Inspect piping for a closed shut off valve Open the shut off valves clean the strainer or remove the shippi...

Page 18: ...18 APP 001b APR 2007 THIS PAGE INTENTIONALLY BLANK...

Page 19: ...ce schedule and the Safety Precautions Sheet supplied with this product Escaping refrigerant can cause injury especially to the eyes and lungs WARRANTY All Hansen products except electronics are guara...

Page 20: ...poration 6827 High Grove Boulevard Burr Ridge Illinois 60527 USA Tel 630 325 1565 Fax 630 325 1572 Toll 800 426 7368 Email info hantech com Web www hantech com USA Asia Europe India Latin America Midd...

Reviews:

Related manuals for APP08