Page EN-32
Fitting and installation
Smallest conductor cross-section
Rated current of the
device in A
nominal cross sec-
tion in mm2
> 3 and ≤ 6
0.75
> 6 and ≤ 10
1.0
> 10 and ≤ 16
1.5
> 16 and ≤ 25
2.5
> 25 and ≤ 32
4
> 32 and ≤ 40
6
> 40 and ≤ 63
10
230 V 1N~ / 50 Hz
L1
N
PE
3
2
1
4
5
L1 to
(bridged)
N to
(bridged)
(PE) to
400 V 2N~ / 50 Hz
L2
L1
N
PE
3
2
1
4
5
L1 to
L2 to
(bridged)
N to
(bridged)
(PE) to
400 V 3N~ / 50 Hz
L2
L3
L1
N
PE
3
2
1
4
5
L1 to
, L2 to
, L3 to
N to
(bridged)
(PE) to
L1 – L3: Phase(s), N: Neutral conductor,
PE: Protective conductor (earth wire)
Inserting the oven
NOTICE
Risk of damage!
■
Do not use the oven door handle to
lift the entire oven! It is not designed
to bear the weight of the cooker. Use
the carrying handles on the sides.
■
Do not set the oven down on the edge
or corner of the oven door! The glass
panes can be damaged.
The following conditions must be fulfi lled:
– The dimensions of the recess must be
600
× 560 × 560
mm (H × W × D).
– The
built-in cabinet
can be equipped with
either ledges/rails or an intermediate shelf
with a ventilation cut-out.
– An intermediate shelf is required if a draw-
er is to be installed below the oven.
– Veneers, plastic coverings and adhesives
which are used must be resistant to heat
(100°C).
1. Sweep or vacuum out any residual wood
shavings.
2. Slide the oven into the built-in cabinet as
far as possible using the carrying han-
dles, in order that the earthing screw and
the connector jack are both easily acces-
sible for the hob.
Summary of Contents for 2013C(G)3.334eETsPrDpHbJX
Page 46: ...Seite DE 46 ...