Options
•
Humidity:
Direct Injection, 10 to 85% RH from 35 to 75
o
C, Capacitance
sensor.
•
HanseView
TM
:
System control of temperature and vibration. Control/Data
Logger, and Control/Data Logger/Analyzer options.
•
Vibration Fixtures:
Specially designed for HALT/HASS applications.
•
LN2 System:
Complete installation, piping and controls
•
Stand-Alone:
Temperature Cycling Chambers or 6dof Vibration Tables in
sizes shown below.
•
Event Output:
Eight event output relay software profile control.
Air circulation:
The chamber is equipped with non-corrosive fans providing air circulation to minimize
chamber temperature gradients. Three phase motors drive the fans. Ba
ffl
es provide
input and output air openings to direct the airflow in the chamber.
Major advantage of Hanse Environmental Inc. chamber is the air circulation
design. This dynamic air circulation was designed to fit
convection cooling
design
and minimize the excessive air for
fan-forced cooling product.
Adjustable Air Flow Plenum:
Thermally conditioned air exits through plenum. 3” ports are also provided to directly
conditioned air to particular areas within the chamber’s working volume.
Air Blower Motors:
Heavy-duty ball bearing type motors are used to drive the air circulator blower. The
blowers are driven by mean of extended stainless shafts. The motors are mounted
vertically, outside the thermally conditioned space to minimize stress on the motor.
NOTE: The direction of rotation of circulators (fans) is very important. The air
circulation must be from the chamber workspace, through the circulators (fans)
past the heaters and back to the chamber workspace. If a circulator is rotating in
the wrong direction (clockwise), two of the three, three-phase power lines must
be switched. The corrected direction should be counter-clockwise.
Authorization and Copyright of this document is
controlled by Hanse Environmental Inc.
16
Summary of Contents for VTC Series
Page 1: ...Operation and Maintenance Instructions for Hanse Environmental Inc VTC Series Rev H 2018 ...
Page 42: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 42 ...
Page 56: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 56 ...
Page 57: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 57 ...
Page 58: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 58 ...
Page 59: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 59 ...
Page 60: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 60 ...
Page 61: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 61 ...
Page 64: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 64 ...
Page 65: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 65 ...
Page 66: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 66 ...
Page 69: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 69 ...
Page 70: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 70 ...
Page 71: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 71 ...
Page 79: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 79 ...
Page 83: ...Authorization and Copyright of this document is controlled by Hanse Environmental Inc 83 ...