10
Justify the Thermostatic Mixer Handle
Set the High Temperature Limit Stop (optional)
Turn the water on to the
handshower.
Turn the thermostatic mixer
handle until the output water
measures 100
o
on a ther-
mometer. Turning the handle
clockwise makes the water
cooler, counter-clockwise
makes the water warmer.
Turn the water off.
Remove the thermostatic mixer handle.
Remove the clip and the stop ring from the stem of the thermo-
static mixer.
Loosen the thermostatic mixer
handle screw. Remove the
handle.
Replace the handle so that
the safety stop override but-
ton is at the 12:00 position.
Tighten the set screw.