Mains supply:
230V~ 60/50Hz
Rated output:
max. 2,5A
Transformer:
Protection class II
Protection Type:
IP 65
Minimum water pressure:
1,5 bar
Applied pressure:
max.10 bar
Recommended pressure:
2 - 5 bar
Test pressure:
10 bar
Hot water temperature:
max. 70° C
Recommended hot water
temperature:
60° C
Cold water temperature:
min. 4°C
Environmental temperature range:
10°C - 45°C
Temperature block:
38°C
Humidity :
Ensure that none of
the electronic com-
ponents are expo-
sed to humidity
Flow diagram
Flow pressure (bar)
Q l/sec
l/min
1 Overhead shower
2 Overhead shower and body showers
From the function is guaranted, the ideal spray
pattern will be reached from 2.0 bar pressure
Flow rate at 3 bar pressure
Overhead shower:
17l/min
Hand shower:
10l/min
Body shower:
15l/min
Hand Body shower:
19l/min
Overhead Hand shower
20l/min
Overhead Body shower
22l/min
N. B. Flow rate will differ then using a pump
T e c h n i c a l d a t a / a i d
Trouble shooting
Failure
No function
Light fails
One halogen spotlight fails
No water flow when using
the shower
Possible Cause
No current available
Transformer defect
Connection to the lighting is
interupted
Halogen spotlight defect
Floor shut-off device is
closed
Shut-off valve (Thermostat)
is closed
Filters are polluted
Remedy
Check current conductor
Replace transformer, contact manufacturer service
Plug in the connector of the lights
Replace halogen bulb (12 V/ 10 Watt)
Open floor shut-off device
Open shut-off valve
Clean filter (Servicing thermostat)