8
9
English
Spare parts
1 thermoelement 94282000
2 shut off unit with selector 96509000
3 knob for thermoelement 96516XXX
4 knob for shut off unit 96517XXX
5 mousseur cpl. 13485000
6 non return valve DW 16 95033000
7 filter 95039000
8 ball s-unions 13989000
9 Elastop shut off unit 94149000
10 knob for shut off unit 96518XXX
11 safety set for temperature control 96470000
12 safety set for flow control 96430000
13 escutcheon 96428XXX
XXX
= Colors
000 chrome
090 chrome/gold
450 white
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Filter are dirty
- Shower filter seal dirty
- Check mains pressure
- Cleaning the filter in the water
connection and at the thermostat
cartridge
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice
versa, when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been
adjusted
- Hot water temperature too low
- Adjust thermostat
- Increase hot water temperature
to 42 °C to 65 °C
Temperature regulation not
possible
- MTC-thermo cartridge calcified - Exchange MTC-thermo cartridge
Shower or spout dripping
- Dirt or sedimentation on valve
seat, shut-off unit damaged
- Clean or exchange shut-off unit
Instantaneous heater didn’t work
with thermostat
- Ecostop ring isn’t removed
Flow limiter in handshower isn’t
removed
- Flow limiter in handshower isn’t
removed
- Filter are dirty
- Non return ralve didn’t move
back
- Remove ecostop ring (12)
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves