6
Assembly
1. Flush through the supply pipes.
2. Mark the holes on the bath rim and drill
(center distance 150 mm).
3. Mount the pillar unions with o-rings and
escutcheons.
4. Fasten the mixer and tighten it.
Hot water connection left hand, cold water
connection on the right hand side.
Large differences in pressure between the hot and
cold water supply should be balanced.
Adjustment
Correction is necessary if the temperature
measured at the take off point differs from the
temperature set on the scale. To adjust please see
page 11.
Operation
The mixer is operated by turning the handle on
the left hand side. The green knob limits the rate
of flow to approx. 10 l/min. If a higher water
consumtion is required press the ECOSTOP button
and turn handle further.
The temperature is selected by turning the
graduated handle on the right side. The flow of
the bath mixer can be changed from tub to
shower function by simply pulling the diverter
knob located at the top of the outlet.
When the water is shut off the flow returns
automatically to the bath function.
Temperature limitation
The temperature is limited by the safety check to 38°
C (100° F). If a higher temperature is required, it is
possible to override the safety stop by depressing
the safety button.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
The mixer is equipped with non return valves and
filters. If the water flow drops the non return valves
need to be cleaned. For that purpous the mixer has
to be removed from the wall. The filters are located
in the connection pieces underneath the connecting
nuts.
English
Attention!
The non return valves must be checked once a year.
Using the Ecostat in conjunction with
combination boilers.
When using the Ecostat with combination boilers,
the Ecostop ring "A" has to be removed.
If fitting a hand shower remove the water limiter
from the shower. (Please see page 12)
Technical Data
Operating pressure:
max. 10 bars
Recommended operating pressure:
1 - 5 bars
Test pressure:
16 bars
Hot water temperature:
max. 80° C
Recommended hot water temp.:
65° C
Rate of flow by 3 bars:
20 l/min
Spare parts
1
thermoelement
94282000
2
shut off unit
94149000
3
knob for thermoelement
96225XXX
4
knob for shut off unit
96228XXX
5
aerator cpl.
13485000
aerator
gold plated
94981990
aerator
fine brass
94981840
6
spout cpl.
92440XXX
7
diverter knob
94102XXX
8
selector cpl.
94103000
9
non return valve DW 15
94074000
10
filter
95039000
11
pillar union
94145XXX
XXX
= Colors
000 chrome plated
030 chr. plated/blue
090 chrome plated/gold plated
330 blue
450 white
490 white /gold
880 satin chrome