TABLE OF CONTENTS

1.  Preliminary Examination ................................................................................................................3
2.  Safety Measures ............................................................................................................................3
3.  General Description & Intended Use ................................................................................................3
4.  Main Features ...............................................................................................................................4
5.  Series Configuration .......................................................................................................................4
6. Specifications ................................................................................................................................5
7.  Probe Dimensions & Cable Connection .............................................................................................7
8. Installation ...................................................................................................................................8
9.  Wiring the Probe to the Controller..................................................................................................11
10. Calibration ................................................................................................................................12
11.  Measurements in Ultrapure Water, 

HI7630-28

zz

 Series Only ........................................................14

12. Maintenance .............................................................................................................................14
13. Accessories ................................................................................................................................15
14. Abbreviations ............................................................................................................................16
Certification ......................................................................................................................................16
Recommendations for Users ...............................................................................................................16
Warranty .........................................................................................................................................16

Dear Customer,

Thank you for choosing a Hanna Instruments

®

 product.

Please read this instruction manual carefully before using this instrument as it provides the necessary information 
for correct use of this instrument as well as a precise idea of its versatility.
This release of the product manual contains information that applies to configuration, specification, installation, 
and calibration of Hanna Instruments industrial conductivity probes.
The 

HI510

 controller is sold separately. Please refer to the controller manual for details on system configurations.

If you need additional technical information, do not hesitate to e-mail us at 

[email protected]

Visit 

www.hannainst.com

 for more information about Hanna Instruments and our products.

Summary of Contents for HI7630-28

Page 1: ...4805 0 to 30 mS cm T 0 to 50 C p max 6 bar SN XXXXXXXXXXXX HI7630 2800 Conductivity and Temperature Industrial Smart Probes Please scan the QR code or follow the link to download the HI510 controller...

Page 2: ...intenance 14 13 Accessories 15 14 Abbreviations 16 Certification 16 Recommendations for Users 16 Warranty 16 Dear Customer Thank you for choosing a Hanna Instruments product Please read this instructi...

Page 3: ...ons detailed in this manual 3 GENERAL DESCRIPTION INTENDED USE HI7630 28 and HI7630 48 are Conductivity and Temperature probes designed to be paired with the HI510 Universal Process Controller The pro...

Page 4: ...conductivity probes can be installed directly in line immersed in a tank or in a flow cell and are suited for continuous measurement of conductivity and associated parameters required in applications...

Page 5: ...h standard solution Process Single point Temperature Range 0 0 to 50 0 C 32 0 to 122 0 F Accuracy 0 5 C 1 0 F Calibration Single point offset controller setting Temperature compensation mode Linear Na...

Page 6: ...ion Salinity Single point with standard solution Resistivity Single point Process Single point Temperature Range 0 0 to 100 0 C 32 0 to 212 0 F Accuracy 0 5 C 1 0 F Calibration Single point offset con...

Page 7: ...189 mm 7 4 Four Ring Probes HI7630 48zz 28 mm 1 1 72 mm 2 8 50 mm 2 12 mm 0 5 3 4 NPT 216 mm 8 5 HI7630 4800 216 mm 8 5 Align the pins and key then push the plug into the socket Rotate the collar to...

Page 8: ...essibility for maintenance when selecting placement Typical installation examples with mounting accessories Accessories are sold separately In line mounting and flow cell installation require that the...

Page 9: ...PT 2 Vent hole 3 O ring 4 Probe Tank immersion with submersible electrode holder I II III 1 2 4 3 5 6 7 9 8 1 Probe cable 2 Cable gland 3 Electrode holder cap 4 Adjustable immersion level 5 Electrode...

Page 10: ...3 and cable gland on top 2 The cable is shielded inside the holder to prevent any damage to the insulation F Tighten the cable gland 2 step III and slide the cap 3 back onto the electrode holder 5 Fl...

Page 11: ...n the board 4 Position excess cable through the cable gland before tightening the nut 5 Remove the ground screw and hardware located below the PROBE connector and attach ground lead g COMM B A IN1 IN2...

Page 12: ...oss contamination when a two point calibration is required use two beakers one for rinsing the probe and the other for calibration Go to Probe Settings in Channel Setup and set Meas Mode to EC Procedu...

Page 13: ...ed in conductivity EC Meas Mode The user can subsequently change Meas Mode to RES to measure in resistivity units M cm Ultrapure water self ionizes into H and OH ions and has a conductivity of 0 055 S...

Page 14: ...ccurate readings Remove and inspect the probe during scheduled service intervals Dry clean the sensor with a soft bristle brush to loosen any debris For a more thorough cleaning Use a cloth and warm w...

Page 15: ...1 2 PVC protective end cap inside height 68 mm 2 6 HI60503 PVDF immersion electrode holder HI60503 2 PVDF protective end cap inside height 68 mm 2 6 HI605011 PVC mounting flange HI60542 In line electr...

Page 16: ...oduced by the user to the supplied equipment may degrade its performance Do not use or store the product in hazardous environments WARRANTY The probes are warrantied for six months against defects in...

Reviews: