background image

19

18

CE DECLARATION OF CONFORMITY

Recommendations for Users

Before using these products, make sure that they are entirely suitable for the
environment in which they are used.

Operation of these instruments in residential areas could cause unacceptable
interferences to radio and TV equipment,

 

requiring the operator to take all neces-

sary steps to correct interferences.

Any variation introduced by the user to the supplied equipment may degrade the
instrument's EMC performance.

In particular cases the instruments could turn off. In such cases they can be
turned on by pressing the ON/OFF key.

To avoid electrical shock, do not use these instruments when voltages at the
measurement surface exceed 24VAC or 60 VDC.

To avoid damages or burns, do not perform any measurement in microwave
ovens.

WARRANTY

All Hanna Instruments meters are guaranteed
for two years against defects in workmanship
and materials when used for their intended
purpose and maintained according to instruc-
tions. The electrodes and the probes are
guaranteed for a period of six months. This
warranty is limited to repair or replacement
free of charge.
Damage due to accident, misuse, tampering
or lack of prescribed maintenance are not
covered.
If service is required, contact the dealer from
whom you purchased the instrument. If under
warranty, report the model number, date of
purchase, serial number and the nature of the
failure. If the repair is not covered by the
warranty, you will be notified of the charges
incurred. If the instrument is to be returned to
Hanna Instruments, first obtain a Returned
Goods Authorization number from the Cus-
tomer Service department and then send it
with shipping costs prepaid. When shipping
any instrument, make sure it is properly pack-
aged for complete protection.
To validate your warranty, fill out and return
the enclosed warranty card within 14 days
from the date of purchase.
All rights are reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner,
Hanna Instruments Inc., 584 Park East Drive,
Woonsocket, Rhode Island, 02895 , USA.

Hanna Instruments reserves the right to
modify the design, construction and ap-
pearance of its products without advance
notice.

Summary of Contents for HI 9057

Page 1: ...Instruction Manual HI 9056 HI 9057 Portable Microprocessor Thermocouple Thermometers Manufacturers since 1978 These Instruments are in Compliance with the CE Directives...

Page 2: ...9056 5 Functional Description Specifications of HI 9057 6 Operational Guide 7 Display Codes Guide 11 Calibration 12 Battery Replacement 12 Shockproof Rubber Boots 13 Accessories 14 Warranty 18 CE Decl...

Page 3: ...sions 180 x 83 x 40 mm 7 1 x 3 3 x 1 6 Weight 350 g 12 4 oz FUNCTIONAL DESCRIPTION AND SPECIFICATIONS FOR HI 9056 Standard features include Interchangeable probes Clear Liquid Crystal Display Two year...

Page 4: ...the C scale Measurements can be performed on either the Centigrade or the Fahrenheit scale BAT HOLD K J T C F HI LO ON OFF 1 Liquid Crystal Display 2 ON OFF Key 3 Reading Memory Hold Key 4 Thermocoup...

Page 5: ...OLD To change the scale press C F once MEASUREMENT RESOLUTION When switched on HI 9056 and HI 9057 default to a 0 1 digit resolution see specifi cations These instruments automatically change the reso...

Page 6: ...reading in the Centigrade scale F The instrument is reading in the Fahrenheit scale HI Displays the highest measured temperature LO Displays the lowest measured temperature HOLD Freezes current readin...

Page 7: ...alibrated at least once a year For an accurate annual recalibration con tact your nearest Hanna Service Center BATTERY REPLACEMENT When the battery is low the user is warned by the BAT indication on t...

Page 8: ...66B Surface probe max 650 C 1200 F 420mm 13 3 280mm 11 100mm 4 16 5 400mm 15 7 260mm 10 2 155mm 6 1 3mm 0 12 200mm 7 8 5mm 0 20 100mm 4 280mm 7 8 3mm 0 12 155mm 6 1 250mm 9 8 3mm 0 12 11 200mm 7 9 ACC...

Page 9: ...cessories HI 710002 Soft carrying case HI710009 Blue rubber boot HI710010 Orange rubber boot 300mm 11 8 30mm 1 2 130mm 5 1 8mm 0 3 HI 766B1 90 surface probe max 450 C 840 F HI 766B2 Surface probe max...

Page 10: ...e probes are guaranteed for a period of six months This warranty is limited to repair or replacement free of charge Damage due to accident misuse tampering or lack of prescribed maintenance are not co...

Page 11: ...ations The reference literature currently covers areas such as Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry and many others New reference material is constantly being...

Reviews: