background image

Hampton HG35-1 Direct Vent Freestanding Gas Stove

5

IMPORTANT:  

SAVE THESE 

INSTRUCTIONS

The  Direct Vent Freestanding Gas Stove must 
be installed in accordance with these instruc-
tions. Carefully read all the instructions in this 
manual  fi rst. Consult the building authority 
having jurisdiction to determine the need for a 
permit prior to starting the installation.

Note:  Failure to follow the instructions 

could cause a malfunction of the 
heater which could result in death, 
serious bodily injury, and/or prop-
erty damage.  Failure to follow these 
instructions may also void your fi re 
insurance and/or warranty.

Note: These instructions take precedence 

over Simpson Dura-Vent instruc-
tions.

SPECIFICATIONS

Fuels: 

HG35-NG is approved for use with 
natural gas.

 

HG35-LPG is approved for use with 
liquefi ed petroleum gases (LPG).

 

HG35-ULPG is approved for use with 
a propane butane mixture (ULPG).

Electrical:

  240V  A.C. system.

Circulation Fan: 

 Two Speed, 125/75.

Log Sets: 

 Ceramic fi bre, 7 per set.

Flue System:

 Coaxial (6-5/8" outer / 4" inner 

liner) rigid fl ue and termination cap.

The effi ciency rating of the appliance is a 
product thermal effi ciency rating determined 
under continuous operating conditions and 
was determined independent of any installed 
system.

INSTALLATION

INSTALLATION AND  REPAIRS 
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED, 
REPAIRED, INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY BY 
A QUALIFIED SERVICE PERSON. 

 

MORE FREQUENT CLEANING MAY 
BE REQUIRED DUE TO EXCESSIVE 
LINT FROM CARPETING, ETC.  IT IS 
IMPERATIVE THAT THE CONTROL 
COMPARTMENT, BURNERS AND 
CIRCULATING AIR PASSAGEWAYS 
OF THE APPLIANCE BE KEPT 
CLEAN.

BEFORE  YOU  START

The HG35 gas stove must be installed in ac-
cordance with these instructions. Carefully read 
all the instructions in this manual fi rst. Consult 
the authority having jurisdiction if you require 
a permit.

DUE TO HIGH TEMPERATURES, 
THE APPLIANCE SHOULD BE 
LOCATED OUT OF TRAFFIC AND 
AWAY FROM FURNITURE AND 
DRAPERIES.

WARNING: FAILURE TO INSTALL 
THIS APPLIANCE CORRECTLY 
WILL VOID YOUR WARRANTY AND 
MAY CAUSE A SERIOUS HOUSE 
FIRE.

CHILDREN AND ADULTS SHOULD 
BE ALERTED TO THE HAZARDS OF 
HIGH SURFACE TEMPERATURES, 
ESPECIALLY THE FIREPLACE 
GLASS, AND SHOULD STAY AWAY 
TO AVOID BURNS OR CLOTHING 
IGNITION.  

YOUNG CHILDREN SHOULD BE 
CAREFULLY  SUPERVISED WHEN 
THEY ARE IN THE SAME ROOM AS 
THE APPLIANCE.  

CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE. 

1)

  Provide adequate clearances for servicing, 

proper operation and around the air openings 
into the combustion chamber. 

2)

  The appliance must be installed on a fl at, 

solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or it can be 
raised up on a platform to enhance its visual 
impact. The appliance may be installed on 
carpeting, tile, wood fl ooring or other com-
bustible material, because the appliance's 
base extends the full width and depth of the 
appliance. The  Direct Vent Freestanding 
Gas Stove can be installed in a wide variety 
of ways and will fi t nearly any room layout. 
It may be installed in a recessed position, 
framed out into the room, or across a cor-
ner.

3)

  The  Direct Vent Freestanding Gas Stove  is 

approved for alcove installations, which meet 
the clearances listed on page 6.  This unit 
is approved for manufactured home instal-
lations, see page 7 and pages 9 and 10 for 
the required fl ue arrangements. If installed 
into a manufactured home the unit must be 
bolted down to the fl oor. 

4)

  This appliance is Listed for bedroom  instal-

lations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.

5)

  This appliance is Listed for Alcove installa-

tions, maintain minimum Alcove clearances 
as follows,   minimum width of 40" (1016mm), 
a maximum depth of 36" (914mm), and 
minimum ceiling height of 64" (1626mm) 
from fl oor to ceiling.

6)

  We recommend that you plan your instal-

lation on paper using exact measurements 
for clearances and fl oor protection before 
actually installing this appliance.  Have a 
qualifi ed building inspector review your plans 
before installation.

Summary of Contents for HG35-NG1

Page 1: ...an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installa...

Page 2: ...DUCTS INTERNATIONAL LTD The HG35 has been designed to provide you with all the warmth and charm of a wood fireplace As it also bears our own mark it promises to provide you with economy comfort and se...

Page 3: ...ome Requirements 7 Combustion and Ventilation Air 7 Flueing Introduction 8 Installation Precautions 8 Safety Precautions for the Installer 8 Flue Restrictor Position 8 Exterior Flue Terminal Locations...

Page 4: ...difference the label on the unit is the correct one DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTICLES ON OR AGAINST THIS AP...

Page 5: ...D AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE CHILDREN AND ADULTS SHOULD BEALERTEDTOTHEHAZARDSOF HIGH S...

Page 6: ...Clearances A Side Wall to Unit 6 1 2 165 mm B Back Wall to Unit 6 152 mm C Vertical Flue Pipe to Back Wall 2 50 mm E Unit Corner to Wall 2 50 mm Unit Top to Alcove Ceiling 36 914 mm Minimum ceiling h...

Page 7: ...l as ensuring that there is adequate accessibility for servicing and proper operation INSTALLATION MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1 Ensure that structural members are not cut or weak...

Page 8: ...ns in walls and ceilings FLUEING INTRODUCTION The HorizontalTermination Kit and the Simpson Dura Vent Direct Vent System Model DV GS venting systems in combination with the Direct Vent Freestanding Ga...

Page 9: ...hanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically...

Page 10: ...ations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow ULPG LPG and Natural Gas Residential Manufactured and Mobile Homes Installations The fluei...

Page 11: ...ns follownational or local code requirements Below Grade Riser Installation If the Riser Termination must be installed below grade i e basement application proper drain age must be provided to prevent...

Page 12: ...eing Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the flue is unrestricted Masonry chimneys may take various contou...

Page 13: ...5o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including flue term...

Page 14: ...the liner onto the 4 dia starter collar 8 Cut the 4 dia flex liner to the desired size Hint leave an extra 12 to 16 of length this will make the final assembly easier to work with 9 Securethe4 dia fl...

Page 15: ...imumclearancerequirementsbetween the outer wall of the flue pipe and nearby com bustible surfaces is 1 1 4 inch Be sure to check the flue termination clearance requirements fromdecks windows soffits g...

Page 16: ...unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is at tached If this is the case you may want to adjust the location of the unit 2...

Page 17: ...ue cap by attaching the two sheet metal strips extending from the flue cap assembly into the outer wall of the flue pipe Use the two sheet metal screws provided to connect the strips to the pipe Bend...

Page 18: ...ion and sealed Diagram 8 5 Cut a hole in the roof centred on the small drilled hole placed in the roof in Step 2 The hole should be of sufficient size to meet the minimum requirements for clearance to...

Page 19: ...n is attached to the support using the eight metal screws provided Be sure there is at least a 2 inch overlap where the extension joins the support CATHEDRAL CEILING Round Support RDS Square Support S...

Page 20: ...be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw...

Page 21: ...908 528 Red LPG label 1 910 037 30 ULPG Pilot Orifice 1 918 579 Instruction Sheet 6 Pull out the pilot hood by hand 7 Remove the pilot orifice with the allen key 8 Put in the new LPG orifice with the...

Page 22: ...outlet pressure and screw it out to decrease it Use a 10 mm wrench Note The outlet pressure must be set to maximum 2 64 kPa 17 Turn on the gas supply and plug in the power cord Cable Electric Modulat...

Page 23: ...Burner Orifice 52 LPG 1 918 149 Decal Converted to 30 6 mj 1 918 148 Instruction Sheet 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock Refer to manual for more...

Page 24: ...2 154 Embers Embers The 02 refer numbers i e 02 43 are molded into the rear of each log 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into...

Page 25: ...proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port Cutout Pin D 02 46 B 02 56 A 0...

Page 26: ...om the sides of the Front Casting 3 Fasten the Right Door to the 2 right hinges 2 screws per hinge Repeat for the Left Door TILE INSET INSTALLATION Side Tile Inset 1 Slide the Standard Side Tile Inset...

Page 27: ...ff of the stove 2 Release the catches on the left and right side of the stove that secure the glass 3 Remove the glass by sliding it up and out 4 Pull all four door hinges out from the sides of the fr...

Page 28: ...Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep...

Page 29: ...losed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the three pieces of door glass are properly positioned Never operate the appliance with any of the glass removed or...

Page 30: ...button once will switch the unit on The unit will resume its last settings If the unit is switched on pressing and releasing this button once will switch the unit off Flame Increase If the unit is swi...

Page 31: ...re provisions for adequate combustion and ventilation air 918 399a WARNING If you do not follow these instructions exactly afireorexplosionmayresultcausingproperty damage personal injury or loss of li...

Page 32: ...AUTHORIZED SERVICE TECHNI CIAN TO INSPECT THE APPLI ANCE AND TO REPLACE ANY PARTOFCONTROLSYSTEMAND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZAR...

Page 33: ...sed with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log sh...

Page 34: ...the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed IMPORTANT These fans collect a lot of dust from within your home Ensure you maintainthesefanmotorsona...

Page 35: ...N A N A N A N A 910 084 Control Box 910 527 Manual Control Switch N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 2 N A 2 2 1 2 3 910 912...

Page 36: ...5 740 048 Baffle for Firebox 46 Heat Exchanger Assy 47 Transition Box Assy 48 740 077 Side Insert Bracket Part Description Part Description Part Description 55 Gasket Transition Box Air Passage 56 W84...

Page 37: ...Hampton HG35 1 Direct Vent Freestanding Gas Stove 37 PARTS LIST...

Page 38: ...Pilot Holder 68 W840470 Pilot Assembly Gasket 69 Valve Shield 70 Valve Bracket 72 Front Support 73 730 528 Rear Log Bracket Assy 75 402 935 Log Set 740 572 Ember Package 78 746 525 Burner Assy 79 Bas...

Page 39: ...ty to the original purchaser of a Regency Product The Warranty Lifetime Covered under the agreement are the following compo nents Combustion chamber heat exchanger burner tubes logs embers glass therm...

Page 40: ...lled ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com au Reasons t...