22
Hampton HG35-1 Direct Vent Freestanding Gas Stove
INSTALLATION
Installer Notice:
These instructions must
be left with the appliance.
Minimum pressure:
Remove one of
the cables connected to the electric
modulator. Keeping the nut (B) blocked,
screw in the screw (C) to increase the
pressure and screw it out to decrease it.
Use a screwdriver 6 x 1 blade.
Note:
The outlet pressure must be set to
minimum 0.74 kPa.
18) Adjusting the Outlet Pressure
.
All the adjustments must be
carried out in the following order:
Remove the modulator plastic cap (A)
using needle nose pliers.
Maximum pressure:
Turn the unit ON
to its highest input rating. Screw in the
nut (B) to increase the outlet pressure
and screw it out to decrease it. Use a 10
mm wrench.
Note:
The outlet pressure must be set to
maximum 2.64 kPa.
17)
Turn on the gas supply and plug in the
power cord.
Cable
Electric
Modulator
After carrying out all adjustments, block
the setting screws with paint, taking care
not to obstruct the breather orifi ce of the
pressure.
Put back the modulator plastic cap.
WARNING:
To ensure the correct
operation of the modulator it is
necessary that the plastic cap (A) is
returned to its original location.
C
B
A
19)
At the end of all setting and adjustment
operations, check electrical insulation
and for any gas leaks.
20)
Close the bottom door, place the logs
and lava rocks back into position, install
the glass front and put in the cast top
back in position.
21)
Check operation of fan and fl ame
control.
22)
Check for proper fl ame appearance and
glow on logs.