10
Hampton HG35-1 Direct Vent Freestanding Gas Stove
INSTALLATION
Offset to Vertical Terminations
FLUEING ARRANGEMENTS
Vertical Terminations Using
Dura-Vent Flueing System for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight verti-
cal and offset to vertical runs with vertical terminations.
Maximum two 45
o
elbows
.
If the fl ue is ENCLOSED in a chase (min. size 9" (229mm) x 9" (229mm)) maintain a 1-1/4"
(32mm) clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Horizontal Terminations for All
Flueing Systems
The shaded areas in the diagram below show
all allowable combinations of vertical runs
with horizontal terminations. Maximum one
90
O
elbow (two 45
o
elbows equal one 90
o
elbow).
ULPG,LPG and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
The fl ueing arrangements diagrammed below,
have a min. of 75% (fl ue loss) effi ciency with Fan
Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
ROTATING 45
O
ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS
1)
Remove all 4 screws that secure
the elbow to the unit using a 1/4"
magnetic nut driver.
2)
Rotate the elbow 180
o
3)
Secure the elbow by securing
it with the 4 screws.
Remove all 4 screws
and washers
Horizontal Run (Feet)
4'9-3/4"(1.47m)Min.
6'(1.8m)
4'9-3/4" (1.5m)
5'(1.5m)
3’
(0.9m)
Min.
1'(0.3m)
10'(3.0m)Max.
13"(4.0m)
1
1
2
2
12
12
14
6
6
16
4
4
14
22
8
8
18
10
10
20
V
ertical
Height
(feet)
20'-6"(6.2)Max.
Restrictor
Position
(A)