Hammer Engines GmbH / IQ-Serie / Instruction Manual
Possible Error messages
Errors messages during startup:
RPM < 2.000 DURING WARMUP/ VORHEIZEN
REASON:
Turbine RPM dropped below 2.000 during warm-up
CAUSE:
Starter voltage is too low during warm-up (Menu 9.16), starter failure, turbine
stuck
RPM < 5.000 DURING RAMPUP
REASON:
Turbine RPM dropped below 5.000 during ramp up
CAUSE:
Starter voltage is too low during ramp up, starter failure, turbine stuck
FLAMEOUT DURING WARMUP/ VORHEIZEN
REASON:
Temperature dropped below 200°C during warm-up.
CAUSE:
Starter voltage too high (Menu 9.16), Fuel rate set too low (Menu 1.8)
FLAMEOUT DURING RAMPUP
REASON:
Die Temperature dropped below 200°C during ramp up.
CAUSE:
Starter voltage too high (Menu 9.19), Fuel feed failure
Errors messages during Auto-Calibration
FLAMEOUT DURING CALIBRATION
REASON:
Temperature dropped below 250°C during calibration.
CAUSE:
Fuel feed interrupted -> User error
RPM DROPPED BELOW MINIMUM CALIBRATION VALUES
REASON:
RPM dropped below values needed for acceleration
CAUSE:
RPM sensor being interfered by ambient light, fuel feed failure (bubbles) ->
User error
ERROR DURING CALIBRATION
REASON:
It was not possible to stabilize calibration RPMs
CAUSE:
Calibration rate set too high (Menu 9.4), fuel feed failure -> User error
CALIBRATION VOLTAGE EXCEEDED
REASON:
The max set Voltage has been exceeded
CAUSE:
The max set Voltage has been set too low (Menu 9.5), fuel feed failure,
fuelpump failure -> User error