26
Hammer Engines GmbH / IQ-Serie / Instruction Manual
FAILSAFE TIMEOUT:
Time between initiation of failsafe trust and complete shutdown, should the glitch or bad
command continue.
FAILSAFE THRUST:
Once the FAILSAFE DELAY has passed the turbine will go to this preset rpm.
Deactivation of the FAIL SAFE Function:
Should you set the value for FAILSAFE DELAY to 0.0 sec, Fail Safe Thrust will be
deactivated.
PCM Transmitter/Receiver FAIL SAFE Settings:
In order to recognize a Fail Safe using PCM radio equipment the radio will have to emit
signals in case of a failsafe that are outside the learned limits. Hence, should you have taught
100% positive and 100% negative travel, then failsafe has to be set to negative 110% and
positive 110%. Please see your radios manual.
Auxiliary channel
Functions as an on/off switch:
ON/OFF Switch (Replaces trim):
The auxiliary channel replaces trim, switch ON = trim up / switch OFF = trim down. Please
note that trim needs to be set to maximum should you want to use this switch function!
Smoker-Valve:
A connected smoker can be operated. This channel will be activated above 300 degrees
Celsius.
Connect the ECU to the receiver using a 1:1 servo cable (PATCHCABEL) on AUX.
RECEIVER