Document #101-0193
14
11/21/07
Coinco®/Mars® Mounting Instructions
In the following section, part quantities are represented by paranthesis
and the # indicates the index number according to the diagram on pages
8-9.
1.
Mount Cover Plate-#14 to Filler Plate-#12 using (2) 10-24 x
3
/
8
Philips
head screws-#13.
2.
Then mount to face of cabinet using (4)
1
/
4
-20 Hex nuts-#3 and (4) internal
lock washers-#4.
3.
Take Slider-#9 and Validator Face Plate-#10 and insert (4) 8-32 x
5
/
8
ball
studs-#11 through Face Plate and insert into front of cabinet. Then take (4)
8-32 nylon nuts-#8 and tighten on ball studs.
4.
Mount (4) 10-32 x
3
/
16
Phillister head screws-#17 to Validator Plate-#7.
Screwing them from inside to out.
5.
Then mount Security Bracket-#1 to the bottom of the two Phillister head
screws so it swings up and down.
6.
Take U-Channel-#5 and place it inside of Validator Plate-#7 and match up
with studs on face of cabinet.
7.
Then by taking (4)
1
/
4
-20 Hex nuts-#3 and (4) 1/4 internal lock washers-
#4, mount to cabinet and tighten down.
8.
Then take Validator and place into U-Channel-#5 and mount it with (4) 8-
32 x
5
/
8
Philips head screws-#2. Then swing Security Plate-#1 up and hook
onto the top two Phillister head screws-#17 of Validator Plate-#7.
9.
For the Coinco® Validator only, take Power Pack Holder-#15 and mount
to studs on door using (2) 6-32 Hex nuts-#16.
10.
For the Mars® Validator only, Take Relay Box-#15 and mount above
Power Box on face of cabinet using (2) 10-24 nylon lock nuts-#16.