Document #101-0193
5
11/21/07
II. INSTALLATION
NOTE: It is very important to read and understand all of these instructions
before attempting installation. HAMILTON WILL NOT BE RESPONSIBLE
FOR INJURY DUE TO IMPROPER INSTALLATION.
Mounting
1.
DURING INSTALLATION, REMOVE ALL MAJOR COMPONENTS FROM
THE CHANGER.
2.
Cut an opening in the wall measuring a minimum of 34-
5
/
8
" H x 9" W for RNS, 34-
3
/
4
" H x 18-
1
/
8
" W for DRS.
3.
Caulk around the outside edge of the opening.
4.
Place the cabinet in the opening and press until the flange is flush on all sides.
5.
Fasten the cabinet by bolting or welding a 2" angle iron on both sides of the cabinet.
Hamilton will not be responsible for injury due to improper installation.
FACEPLATE
: 38
5
/
8
" H x 12" W for RNS, 38
1
/
4
" H x 21
5
/
8
" W for DRS.
Reference Appendix (D & E on pages 22 & 23)
Electrical
This changer is operated on 120 VAC, 60 Hz. This changer uses a 5 AMP CIRCUIT BREAKER. This unit
may be hard-wired with conduit if desired.
A GROUND FAULT INTERRUPTER IS REQUIRED.
The
recommended Ground Fault Interrupter should have the following specifications:
• 120 VAC
• 15 AMP
• 6-10mA trip level
• Should
not
trip when power is removed from circuit.
Attached to the main harness is a 1-pin white Molex connected to a white wire. There should be a bright
yellow tag attached to this wire with the following warning:
WARNING: For security reasons, this plug should remain disconnected until
such time as you need to utilize the hopper’s manual run switch.
There is no need to connect this plug for normal operation. If for some reason you wish to utilize the manual run
switch, be sure to unplug the Molex afterward.