General information regarding the CE marking

HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by HAMEG is based on the actual generic- and product stan-
dards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and 
light industry are applied. Regarding the immunity (susceptibility) the limits for industrial environment have been used.

The measuring- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For 
different applications the lines and/or cables used may be different. For measurement operation the following hints and conditions regarding emission 
and immunity should be observed:  

1. Data cables

For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. 
Without a special instruction in the manual for a reduced cable length, the maximum cable length of a dataline must be less than 3 meters and not be 
used outside buildings. If an interface has several connectors only one connector must have a connection to a cable.

Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables HZ72S and HZ72L from HAMEG are 
suitable.

2. Signal cables

Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for 
a shorter length, signal lines must be less than 3 meters and not be used outside buildings.

Signal lines must screened (coaxial cable - RG58/U). A proper ground connection is required. In combination with signal generators double screened 
cables (RG223/U, RG214/U) must be used.

3. Infl uence on measuring instruments.

Under the presence of strong high frequency electric or magnetic fi elds, even with careful setup of the measuring equipment an infl uence of  such 
signals is unavoidable.
This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments spe-
cifi cations may result from such conditions in individual cases.

4. RF immunity of oscilloscopes.

4.1 Electromagnetic RF fi eld

The infl uence of electric and magnetic RF fi elds may become visible (e.g. RF superimposed), if the fi eld intensity is high. In most cases the coupling 
into the oscilloscope takes place via the device under test, mains/line supply, test leads, control cables and/or radiation. The device under test as well 
as the oscilloscope may be effected by such fi elds.

Although the interior of the oscilloscope is screened by the cabinet, direct radiation can occur via the CRT gap. As the bandwidth of each amplifi er stage 
is higher than the total –3dB bandwidth of the oscilloscope, the infl uence RF fi elds of even higher frequencies may be noticeable.         

4.2 Electrical fast transients / electrostatic discharge

Electrical fast transient signals (burst) may be coupled into the oscilloscope directly via the mains/line supply, or indirectly via test leads and/or control 
cables. Due to the high trigger and input sensitivity of the oscilloscopes, such normally high signals may effect the trigger unit and/or may become 
visible on the CRT, which is unavoidable. These effects can also be caused by direct or indirect electrostatic discharge.  

KONFORMITÄTSERKLÄRUNG

DECLARATION OF CONFORMITY
DECLARATION DE CONFORMITE

Hersteller 

 

HAMEG Instruments GmbH 

 

Manufacturer Industriestraße 

 

Fabricant  

D-63533 

Mainhausen

Die HAMEG GmbH bescheinigt die Konformität für das Produkt
The HAMEG GmbH herewith declares conformity of the product
HAMEG GmbH déclare la conformite du produit

Bezeichnung / Product name / Designation: 

  Oszilloskop/Oscilloscope/Oscilloscope

Typ / Type / Type: 

HM303-6

mit / with / avec:   

Optionen / Options / Options:   

mit den folgenden Bestimmungen / with applicable regulations / avec les directives 
suivantes

 

EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG

 

EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC

 

Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE

Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE

15.01.2001

Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonisées 
utilisées

Sicherheit / Safety / Sécurité

EN 61010-1: 1993  / IEC (CEI) 1010-1: 1990 A 1: 1992 / VDE 0411: 1994
EN 61010-1/A2: 1995 / IEC 1010-1/A2: 1995 / VDE 0411 Teil 1/A1: 1996-05
Überspannungskategorie / Overvoltage category / Catégorie de surtension: II
Verschmutzungsgrad / Degree of pollution / Degré de pollution: 2

Elektromagnetische Verträglichkeit / Electromagnetic compatibility / 
Compatibilité électromagnétique

EN 61326-1/A1 
Störaussendung / Radiation / Emission: Tabelle / table / tableau 4; Klasse / Class / Classe B.
Störfestigkeit / Immunity / Imunitee: Tabelle / table / tableau A1. 

EN 61000-3-2/A14
Oberschwingungsströme / Harmonic current emissions / Émissions de courant harmoni-
que: Klasse / Class / Classe D.

EN 61000-3-3
Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / 
Fluctuations de tension et du fl icker.

Datum /Date /Date                                   Unterschrift / Signature /Signatur 

                                                                                 E. Baumgartner
                                                               Technical Manager /Directeur Technique

HAMEG Instruments GmbH

General information regarding the CE marking

For IEEE-bus purposes the double screened cable HZ72 from HAMEG is suitable.

Summary of Contents for HM303-6

Page 1: ...O s c i l l o s c o p e H M 3 0 3 6 Manual English...

Page 2: ...lifiers 12 X Y Operation 13 Phase comparison with Lissajous figures 13 Phase difference measurement 13 in DUAL mode 13 Phase difference measurement in DUAL mode 14 Measurement of an amplitude modulati...

Page 3: ...effected by such fields Although the interior of the oscilloscope is screened by the cabinet direct radiation can occur via the CRT gap As the bandwidth of each amplifier stage is higher than the tot...

Page 4: ...oise Amplifiers Time Base 0 2 s 100 ns cm with X Magnification to 10 ns cm Triggering from 0 to 50 MHz from 5 mm signal level 100 MHz 8 mm Analog mode provides unexcelled signal presentation at high r...

Page 5: ...1 s div 1 2 5 Sequence Accuracy 3 Variabel uncalibrated 2 5 1 to 0 5 s div X Magnification x 10 up to 10 ns div Accuracy 5 Hold Off Time variable to approx 10 1 XY Bandwidth X Amplifier 0 2 5 MHz 3 d...

Page 6: ...Without pulling the locking knobs they will latch in into the next locking position Handle mounting dismounting The handle can be removed by pulling it out further depending on the instrument model in...

Page 7: ...e atmosphere or if there is danger of explosion The operating position may be any however sufficient ventilation mustbeensured convectioncooling Prolongedoperationrequires the horizontal or inclined p...

Page 8: ...83 times the potential difference in Vpp The relationship between the different voltage magnitudes can be seen from the following figure Voltage values of a sine curve Vrms effective value Vp simple p...

Page 9: ...frequency Depending on the time base setting of the TIME DIV switch one or several signal periods or only a part of a period can be displayed The time coefficients are stated in s div ms div and s div...

Page 10: ...d The attenuator switch must then be turned back to the left until the vertical signal height is only 3 8div With a signal amplitude greater than 160Vpp an attenuator probe must be inserted before the...

Page 11: ...be visible after a short warm up period of approx 10 seconds Adjust Y POS I and X POS controls to center the baseline Adjust INTENS intensity and FOCUS controls for medium brightness and optimum sharp...

Page 12: ...is slightly more difficult but causes a better result The rising edge should be as steep as possible with a pulse top remaining as straight and horizontal as possible After completion of the HF adjus...

Page 13: ...uite simple with the following formula and a pocket calculator with trigonometric functions Apart from the reading accuracy the signal height has no influence on the result The following must be noted...

Page 14: ...tion F 1 MHz f 1 kHz m 50 UT 28 3 mVrms If the two values a and b are read from the screen the modulation factor is calculated from where a UT 1 m and b UT 1 m The variable controls for amplitude and...

Page 15: ...a positive potential That has nothing to do with zero or ground potential and absolute voltage values The positive slope may also lie in a negative part of a signal A falling edge sign triggers when...

Page 16: ...ossible in this trigger mode External triggering The internal triggering is disconnected by depressing the TRIG EXT button The time base can be triggered externally via the TRIG EXT socket using a 0 3...

Page 17: ...are required The test leads are connected to the insulated socket and the adjacent ground socket beneath the screen The component can be connected to the test leads either way round After use to retu...

Page 18: ...can be identified by comparison with a known diode Testing Transistors Three different tests can be made to transistors base emitter base collector and emitter collector The resulting test patterns ar...

Page 19: ...soldered This terminal should then be connected to the insulated COMP TESTER socket avoiding hum distortion of the test pattern Another way is a test pattern comparison to an identical circuit which i...

Page 20: ...II display SLOPE Selects the slope of the trigger signal Element Function SLOPE rising edge pushbutton switch falling edge TR LED lights if sweep is triggered LED LEVEL Adjustment of trigger level kno...

Page 21: ...ast 2 5 fold For time measurements turn to right hand stop Element Function XY Selects X Y operation pushbutton switch stops sweep X signal via CH I Attention Phosphor burn in without signal TRIG EXT...

Page 22: ...ggering TRIG EXT pushbutton depressed sync signal 0 3Vpp to 3Vpp to TRIG EXT socket Line triggering normal triggering AT NM and ALT pushbuttons depressed Select trigger coupling with TRIG MODE selecto...

Page 23: ...M A N U A L H A N D B U C H M A N U E L...

Page 24: ...stra e 6 A Rohde Schwarz Company D 63533 Mainhausen registrierte Marke Tel 49 0 61 82 800 0 DQS Zerti kation DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales hameg de Oscilloscopes S...