background image

 

 

 

 

 

 

 

WARRANTY 

 

Hamar Laser Instruments, Inc., warrants each instrument and other articles of 

equipment manufactured by it to be free from defects in materials and 

workmanship under normal use and  service, its obligation under this warranty 

being limited to making good at its factory any instrument and other article of 

equipment which shall, within one year after shipment of each instrument and 

other article of equipment to the original purchaser, be returned intact to Hamar 

with transportation prepaid, and which Hamar’s examination shall disclose to 

Hamar’s satisfaction to have been thus defective; other than this express 

warranty, Hamar neither assumes nor authorizes any other persons to assume for 

it any other liability or obligation in connection with the sale of its products. 

 

This warranty is not applicable to instruments or other articles of equipment 

manufactured by other companies and limited by a warranty extending for less 

than one year. In such an event, the more limited warranty applies to said 

instrument or article of equipment. 

 

This warranty shall not apply to any instrument or other article of equipment 

which shall have been repaired or altered outside the Hamar factory, nor which 

has  been subject to misuse, negligence, or use not in accord with instructions 

furnished by the manufacturer. 

 

The software described in this manual is furnished under a license agreement and 

may be used or copied only in accordance with the terms of the agreement.  It is 

against the law to copy the software on any medium for any purpose other than 

the purchaser's personal use. 

 

The information in this manual is subject to change without notice. No part of 

this manual may be reproduced by any means, electronic or mechanical, without 

written permission from Hamar Laser Instruments, Inc. 

 

©  Copyright Hamar Laser Instruments, Incorporated, 2019 

5 Ye Olde Road, Danbury, Connecticut 06810 

 

Summary of Contents for Dual Scan L-732

Page 1: ......

Page 2: ...ing the alignment measurements For best results do not start taking measurements until the recommended warm time has passed It is always a good metrology practice to periodically check your reference...

Page 3: ...ticles of equipment manufactured by other companies and limited by a warranty extending for less than one year In such an event the more limited warranty applies to said instrument or article of equip...

Page 4: ...al Pitch Axis 13 Checking the Levels for Accuracy 13 Measurement Overview 14 Selecting Reference Points on Machine Tools 14 Selecting Reference Points on Process Mills 14 Measurement Summary 15 Measur...

Page 5: ...sfer line wing bases Injection molding machines and presses Aircraft assembly seat track alignment setting water butt and station planes wing to body and body to body join alignment etc Roll paralleli...

Page 6: ...and targets fit into a small portable shipping case Diode laser 2 times more stable than HeNe based laser systems Battery or AC powered Laser planes flat to arc seconds 00003 in ft or 0 0025mm m in 18...

Page 7: ...to body and body to body join alignment etc Saw mills Vertical press alignment Measuring and aligning The flatness of almost any horizontal or vertical surface squares frames ways flanges circles etc...

Page 8: ...p times Applications for alignments with tolerances of 00002 in ft or 0 0017 mm m or higher Roll parallelism in paper mills printing presses and film lines Leveling almost any surface squares frames w...

Page 9: ...m stability Applications for alignments with tolerances of 00015 in ft or 0 01 mm m or greater Normal or blown film lines roll alignment Rubber roll alignment Leveling almost any surface squares frame...

Page 10: ...ine adjustments see Figure 1 Number of laser planes the L 743 and the L 733 have three laser planes and the L 742 and L 732 have two laser planes that can be factory configured for two vertical planes...

Page 11: ...parallel to your references However doing this may result in some laser drift Accordingly if you use the laser prior to the warm up period it is recommended that you go back and check your references...

Page 12: ...on speed control This control slows the scanner spin until you can see the laser beam pass over the target the farther away the target is located the slower the turret must spin Figure 3 shows control...

Page 13: ...ure calibrates only one level vial at a time and must be repeated for the other axis Note 2 It is very important to warm up the laser for at least 30 minutes before starting this procedure It is also...

Page 14: ...alibration of the Level Vials Roll Axis Note It is very important to warm up the laser for at least 30 minutes before starting this procedure It is also very important to level both the Pitch and Roll...

Page 15: ...tance between the points The result is the calibration of the level vial in units of in ft or mm m To be within specifications the calibration result should be as follows Split Prism Vial Assembly 000...

Page 16: ...ulating the Calibration of the Levels Vials Pitch Axis 1 Level the laser Rotate the entire laser unit 90 to calibrate the Pitch Axis level vial Using the adjustment knobs level the laser so that both...

Page 17: ...Pitch Axis level you are adjusting Using the wrench provided adjust the level assembly until the bubble is centered in the window for the Standard Level vials or the two halves of the bubbles line up...

Page 18: ...rence points carefully Poor reference points like those on the heavily worn portion of a machine bed where all the work is performed may mean extra time to bring the machine back into tolerance In oth...

Page 19: ...d one vertical laser plane are needed 1 Mount a target horizontally at the closest reference point to the laser and adjust the target so that it detects the laser 2 Zero the target and move it to the...

Page 20: ...ts described in Measuring Straightness and Measuring Flatness to determine the straightness and flatness of the machine s axes measuring squareness is a simple process To truly measure squareness one...

Page 21: ...e error from the laser not being parallel to the surface Level to Earth Measurements The leveling of machine tools surface plates and different types of bases can be performed using scanning lasers as...

Page 22: ...ny three points on a surface may be used however Hamar Laser recommends the setup illustrated in Figure 12 Figure 12 Three Point Buck in Using One Target recommended setup When performing this procedu...

Page 23: ...ing the Three Point Buck In 1 Center the target in the Near Position With the target in the Near Position zero the target 2 Move the target to Far Position A and tilt the laser beam until the readout...

Page 24: ...he laser beam must be adjusted to be parallel to or coincident with an edge or centerline The process of making that adjustment is called bucking in This section describes two types of buck in methods...

Page 25: ...resents the distance from the laser to the first target L2 repre sents the distance be tween the two targets If L1 is less than one tenth of L2 the normal buck in procedure is used If L1 is greater th...

Page 26: ...ding is to L2 Stated mathematically the ratio is Set L1 Far L2 If L1 L2 and the far reading are known the set can then be determined by the following formula Set Far reading L1 L2 Note This is a simpl...

Page 27: ...two targets When using normal buck in the rule is Zero Near Point Far Buck in the laser beam by zeroing it on the near target and then pointing the laser beam using the appropriate adjustment knobs t...

Page 28: ...eck A C power source Use second A C power supply if available 5 Noisy target A 1519 1520 readings on PDA NOTE On average the user can expect 00002 in ft to 00005 in ft 0 0025 mm m 0 004 mm m of noise...

Page 29: ...low or high on target window it should be near the window It is possible for the laser to activate the auto wake up feature of target but not enough of the beam is hitting the PSD target sensor to get...

Page 30: ...ime Error in software Do not unplug the A 910 from the USB port while still using the program Report to HLI the exact key strokes that created the Runtime Error 12 Software crashes upon loading Ensure...

Page 31: ...27 Appendix B Equipment Drawings L 733 Precision Geometry Laser...

Page 32: ...28 L 743 Ultra Precision Geometry Laser...

Page 33: ...29 The L 732 Dual Scan Precision Roll Alignment Laser...

Page 34: ...30 The L 742 Dual Scan Ultra Precision Roll Alignment Laser...

Page 35: ...ted This makes is very likely that the error in measurement at the point where the target is zeroed is nearly identical to the error in each subsequent measurement because the difference in sensor are...

Page 36: ...ea is 1 micron or less Approx 4 mm of measuring area each vertical line on the graph equals 1 mm Total Error 3 3 microns 2 microns 2 microns 0 000 Each green vertical line equals 1 mm of measuring are...

Page 37: ...the type intended for nail polish removal NOTE When cleaning precision optics even with the best quality optical cleaning tissue use gentle pressure to avoid scratching the surface or damaging the opt...

Reviews: