background image

10

6.2 Alarm

• In the event of an alarm - as soon as the smoke

detector detects combustion particles or when
carrying out the simulation (see

7.2. Alarm

simulation

) - the

LED

flashes once per second

and an alarm signal sounds.
Alarm signal: sustained pulsating tone
(BI 0.5s - Pause 0.5s - BI 0.5s - Pause 0.5s -

wBI 0.5s - Pause 1.5s)

• The alarm continues until the smoke detector no

longer detects combustion particles in the air,
you - in the event of a false alarm - activate mute
mode (see

6.4. Mute mode

) or end the alarm

simulation.

Warning

The triggering of an alarm always requires
your immediate attention and the taking of
appropriate action!

6.3 What to do in the event of an alarm
(recommendation)

Save yourself and others

• Keep calm!
• Warn other family members and/or fellow

residents!

• Now leave the house immediately and close all

doors and windows of your escape route - if this
can be done safely - to slow down the spread of
smoke and

fi

re.

• After leaving the house, go to your agreed

assembly point and make sure that everyone has
left the house.

Call the fire brigade

Call the

fi

re brigade as soon as you are safe.

Attempts to extinguish

Only attempt to extinguish the

fi

re yourself if you do

not endanger yourself (or others) and if you have
suitable extinguishing agents.

6.4 Mute mode (in the case of a false alarm)

Warning

Before activating mute mode, clarify the cause of
the alarm and make sure that there is no further
danger!

Note

• Cigarette smoke will not normally trigger the

alarm unless the smoke is blown directly into
the smoke detector.

Note

• Water vapour produced during cooking can

trigger an alarm if the smoke detector is
located near cooking points.

• If an alarm is triggered, check whether it is

actually an emergency.

• If there is

fi

re or smoke, call the

fi

re brigade or

act as in

6.3. What to do in the event of

an alarm (recommendation)

.

• Once you have ensured that it is a false alarm,

press the

TEST

button on the smoke detector to

silence the alarm for about 10 minutes.

• The red LED will then

fl

ash once every 8 seconds to

indicate that the smoke detector is in mute mode.

• The smoke detector is automatically reset after

approx. 10 minutes. If smoke particles are still
present after this period, the alarm is triggered
again.

• Mute mode can be operated repeatedly.

7. Care and maintenance

7.1 Testing

Press the

TEST

button on the smoke detector. The

signal sound is heard when the electronics, sensor,
siren and battery are working.

Note

• Immediately replace smoke detectors that no

longer function correctly with new devices.

• It is recommended to test the unit weekly to

ensure proper functioning.

• Test the smoke detecto

ONLY

using the

TEST

button. Never use an open

fl

ame, lighters, etc.

to simulate an alarm and test the function.

Summary of Contents for 00223842

Page 1: ...Smoke Alarm GS526 Rauchwarnmelder 00 223842 D GB Operating Instructions Bedienungsanleitung...

Page 2: ...f any kind of damage the smoke detector must be replaced Draw up an escape plan in case of emergency see 6 1 for instructions The escape plan recommendation Warning of hearing damage The smoke detecto...

Page 3: ...om Child s room Bath room Corridor Smoke detector for minimum protection Smoke detector for optimal protection Installation locations with restrictions In buildings with several residential units smok...

Page 4: ...ork Construction work cleaning work with dust generation Strong electromagnetic effects Significant temperature fluctuations which can lead to condensation of the humidity in the smoke detector etc If...

Page 5: ...hen and water vapour can be excluded When installing the smoke detector near dishwashers washing machines ovens etc keep it at least 3 m away from these areas When installing the smoke detector near v...

Page 6: ...itchens that serve as escape routes Corridors and rooms with a width 1 m the ideal installation location is on the ceiling centrally between the walls Corridors with a width 3 m in corridors with a ma...

Page 7: ...rooms For pitched roofs with a roof pitch 20 the smoke detector must be installed at a distance of at least 0 5 m and max 1 m from the gable peak see Fig 5a 0 5 m 0 5 m 20 5a Note the following for r...

Page 8: ...s are higher than 0 2 m and the area of the individual ceiling panels is less than 36 m each the joists beams are not relevant and are to be seen as part of the ceiling The smoke detector can be insta...

Page 9: ...tach the smoke detector to the base plate affixed to the installation location by inserting the latching hooks into the openings provided and turning the smoke detector clockwise Check that the smoke...

Page 10: ...Mute mode in the case of a false alarm Warning Before activating mute mode clarify the cause of the alarm and make sure that there is no further danger Note Cigarette smoke will not normally trigger...

Page 11: ...ce the smoke detector with a new device Ensure that all specifications are met according to the installation location see 4 Installation In the event of structural recognisable changes check whether t...

Page 12: ...h red LED flash repetition of alarm scheme Temperature range 5 C 40 C 12 LED and acoustic signalling LED flashes every 40 seconds The smoke detector is working properly LED flashes every second and al...

Page 13: ...Installationshinweise Bei jeglicher Art von Besch digung ist der Rauchwarnmelder auszutauschen Erstellen Sie f r den Notfall einen Fluchtplan Hin weise dazu finden Sie unter 6 1 Der Fluchtplan Empfeh...

Page 14: ...rschriften f r die Installation 4 1 Allgemeine Hinweise F r die Mindestabsicherung wird empfohlen je einen Rauchwarnmelder in jedem Schlaf und Kinderzimmer sowie in Fluren die zu diesen R umen f hren...

Page 15: ...und Umgebungen neigen aufgrund ihrer typischen Nutzung m glicherweise beg nstigt zur Ausl sung von Fehlalarmen Darunter fallen St rfaktoren wie z B Wasser Koch und sonstige D mpfe Schwei L t Trenn un...

Page 16: ...eitig Fehlalarme durch K chen und Wasserdampf ausgeschlossen werden k nnen Halten Sie bei der Installation des Rauchwarn melders in der N he von Geschirrsp lern Waschmaschinen fen etc mindestens 3 m A...

Page 17: ...4 3 8 Wandmontage beschrieben zu bevorzugen Flure und R ume mit einer Breite 1 m Der ideale Montageort ist an der Decke mittig zwischen den W nden Flure mit einer Breite 3 m In Fluren mit einer maxim...

Page 18: ...3 5 Standard R ume Bei Spitzd chern mit einer Dachneigung 20 ist der Rauchwarnmelder in einer Entfernung von mind 0 5 m und max 1 m von der Giebelspitze anzubringen siehe Bild 5a 0 5 m 0 5 m 20 5a Be...

Page 19: ...er einzelnen Deckenfelder jeweils kleiner als 36 m sind die Unterz ge Balken nicht relevant und als Bestandteil der Decke zu sehen Der Rauchwarn melder kann auf einem Deckenfeld oder direkt auf dem Un...

Page 20: ...gen Sie den Rauchwarnmelder auf der an der Montagestelle angebrachten Grundplatte indem Sie die Rasthaken in die vorgesehenen ffnungen einf hren und den Rauchwarnmelder im Uhrzeigersinn drehen Kontrol...

Page 21: ...vieren kl ren Sie die Ursache f r den Alarm und vergewissern Sie sich dass keine weitere Gefahr besteht Hinweis Zigarettenrauch wird normalerweise den Alarm nicht ausl sen au er der Rauch wird direkt...

Page 22: ...Risse im Geh use aufweist Sollte dies der Fall sein ersetzen Sie den Rauchwarnmelder durch ein neues Ger t Stellen Sie sicher dass alle Vorgaben entsprechend des Montageorts siehe 4 Montage eingehalte...

Page 23: ...iederholung des Alarmschemas Temperaturbereich 5 C 40 C 12 LED und akkustische Signalisierung LED blinkt alle 40 Sekunden Der Rauchwarnmelder funktioniert ordnungsgem LED blinkt jede Sekunde und Alarm...

Page 24: ...corresponding companies Errors and omissions excepted and subject to technical changes Our general terms of delivery and payment are applied Hama GmbH Co KG 86652 Monheim Germany Service Support www h...

Reviews: