![Halyard Exhaust Alert Mk3 Installation & Operating Instructions Manual Download Page 8](http://html1.mh-extra.com/html/halyard/exhaust-alert-mk3/exhaust-alert-mk3_installation-and-operating-instructions-manual_3380922008.webp)
Exhaust Alert Operating & Fitting Instructions
6
HMI 201/01
•
Ensure there is adequate space behind mounting position for the gauge body
and cable. There needs to be a minimum of 75mm clearance from the
mounting panel face to accommodate the unit correctly.
•
Mark the centre of the gauge desired position and drill the mounting hole with
a 53mm hole cutter. It is recommended that a pilot hole is drilled first, and
its location is checked before proceeding with cutting the hole.
•
Clean up the hole edges as necessary removing any sharp edges.
•
Ensure the gauge seal is in place against the bezel and pass the gauge cable
through the hole and then through the gauge backing nut on the inside of the
panel.
•
Locate Display unit into hole and slide backing nut up the cable, around the
units’
body and tighten sufficiently by hand to seal and hold the unit in place
as shown in Fig 3.
•
Run the cable to the connection block.
Fig. 3. Through Panel Gauge Mounting