Instruction Manual PSx3xxPN
6
Solid shaft:
The PSx3xxPN is mounted on the machine by fixing the solid shaft with coupling and
intermediate flange to the axis of the machine.
Never apply force to the housing cover, e.g., for supporting weight
.
Driving the PSx3
xxPN rearward is prohibited (e.g. it’s not allowed to turn the
output shaft by an external force)
.
2.3
Pin assignment
For the supply voltage either a Binder series 713/763 (A-coded) round, 5-pin plug for
PSE and PSS devices or a 5-pin Harting plug with protective sleeve (HAN4A) for the
PSE34xx devices is located in the housing cover of the PSx3xxPN.
Two round 4-pin sockets, Binder series 825 (D-coded) are provided for connection to
the bus.
Supply voltage connector:
round plug
Harting plug
1. +24V motor
2. ground (motor)
3. +24V control unit
4. ground (control unit)
5. housing/pressure balance
(external top view)
To prevent the ingression of fluids into the PSW-housing during
cooldown, use a special cable with an airtube for pressure balancing
of your PSW
Round socket for bus:
1. TD+ (WH/GN, white/green)
2. RD+ (WH/OG, white/orange)
3. TD- (GN, green)
4. RD- (OG, orange)
(external top view)
Due to the use of 4-pin sockets, only four-wire cables should be used
.
Electrical grounding:
Next to the connecting plugs there is a M4 stud bolt. It is recommended to connect
the positioning system with a cable as short as possible to the machine base. The
minimum wire cross section therefor is 1.5mm².