Instruction Manual PSx3xxPN
22
Bit 11
: manual displacement
This bit is set:
- if, while on standstill, the drive is turned externally by more than the value in
the positioning window after a positioning run has been finished correctly
This bit is reset:
- with each new run command
Bit 12
: incorrect target value
This bit is set:
- when a transferred target value lies outside of the limit switches; also
caused, for instance, because of the actual value of the reference value (Par.
40)
- when a transferred target value lies inside of the limit switches; but because
of a necessary loop run the specified interval would be left
This bit is reset:
- with each new run command
Bit 13
: motor power was missing
This bit is set:
- if the power to the motor is less than the Umot limit (Par. 90) or above 30V
when initiating a positioning run or a manual run
- if during the run the voltage leaves the given corridor
This bit is reset:
- if the power to the motor is above the Umot limit and below 30V when
initiating a positioning run or a manual run
Bit 14 / 15
: positive / negative range limit
This bit is set:
- if the limit value is reached during a manual run (but not if reached during a
positioning run)
- if a limit value is modified such that the current position lies beyond the limit
- if, while on standstill, by means of an external force the drive is moved to a
position which is outside the area which is defined by the range limits
This bit is reset:
- as soon as the actual position is again inside the range limits (Exception:
After the end of a manual run the drive is located still at the range limit within
the positioning window and no new run command was issued yet.)
c) Detailed description of control bits
Bit 0
:
manual run to larger values
Bit 1
:
manual run to smaller values