background image

Page 1

1000004727  (Rev. A - 09/18)

HAC-HB*1C     HAC-HB-NF-*1C

HTHB-HAC 

Retrofit Hydroboost

®

 Bottle Filling Station

HTHB-HAC Bottle Fillers are among the easiest to install on the market today. 

To insure you install these models easily and correctly,  PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR 

INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER 

APPLICABLE CODES. After installation, leave these instructions with the Fountain 

for future reference.

IMPORTANT

THIS IS AN INDOOR APPLICATION ONLY.  

ALL SERVICE TO BE PERFORMED BY AN

 AUTHORIZED SERVICE PERSON.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES 

IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE 

BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN 

ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. 

THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS 

PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN 

FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER 

COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).

INSTALLER

TOOLS REQUIRED

BUT NOT PROVIDED:

SAFETY GLASSES

GLOVES

ELECTRIC DRILL

3/4” WRENCH OR CRECENT 

WRENCH

UTILITY KNIFE

TAPE MEASURE

PENCIL

5/32” ALLEN WRENCH

Installation and Use Manual

Summary of Contents for HydroBoost HTHB-HAC

Page 1: ...CTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEE...

Page 2: ...Before proceeding Disconnect electrical power supplying the water cooler Switch circuit breaker OFF or remove fuse Unplug water cooler power cord from electrical outlet Shut off water supply NOTE On T...

Page 3: ...emove the protective covering from the basin Reinstall the drain elbow drain plug and strainer plate on to the new basin Attach the new drain hardware onto the new basin Exchange Bubbler hardware WATE...

Page 4: ...ck the o rings Loosen the locknut and push tube end past both o rings to a positive stop in the filter head recess approx 1 Locknut may have to be backed out a little more Screw the locknut hand tight...

Page 5: ...filter and the water inlet using the supplied 3 8 x3 8 union connector Discard in line strainer Single Level Models Two Level Models HWF3000 WATERSENTRY PLUS FILTER INSTALLATION With Filter Fig 1 Sing...

Page 6: ...into insulation Insert 1 4 poly tube into the Regulator Outlet unmarked Opposite end of 1 4 poly tube will be inserted later into the Bubbler RE PLUMBING SINGLE STATION WATER CIRCUITS NON FILTER CAUTI...

Page 7: ...ut the Evaporator Outlet 1 4 poly tubing 6 from the Evaporator Outlet and insert the 1 4 Tee fitting between the two pieces Connect Bottle Filler supply line to Tee fitting Remove 1 4 poly tubing from...

Page 8: ...TOR L H DUMMY UNIT R H REFRIGERATED UNIT HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON RH SIDE SEE NOTE 2 1 Add water supply to Bottle Filler to be located on LH unit In the left hand unit cut th...

Page 9: ...D UNIT CAUTION This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly When disconnecting water lines use a container to catc...

Page 10: ...w Basin Assembly Reposition Basin Assembly Basin with Drain and Bubbler hardware back onto the cooler Reattach drain line to P trap and tighten 3 Fasten Basin Assembly in place Insert and retighten th...

Page 11: ...ound boss in gasket fits in hole of basin 9 Once Bottle Filler is installed on wall plate tabs water line and power cord are installed properly push top of Bottle Filler toward wall and line up top co...

Page 12: ...Page 12 1000004727 Rev A 09 18 HAC HB 1C HAC HB NF 1C BOTTLE FILLER GASKET Fig 9 Fig 10...

Page 13: ...ill scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button...

Page 14: ...Mtg Brkt John Guest Fittings Screws 1 2 3 55898C 98926C 0000000746 DESCRIPTION PART NO FILTER PARTS LIST See Fig 12 DESCRIPTION 98543C 98544C 1000004573 98546C 98547C 98549C 98668C 98669C 98670C 0000...