Determining Room Re-Entry Time

The HaloFogger EXT is designed for disinfecting small spaces. If venting to the outside can be safely 
achieved you can do so after 90 minutes. Otherwise follow the minimum wait times below.

Whenever possible, delay re-entry and allow treated room to remain unoccupied overnight. Otherwise, 
select the appropriate room re-entry time directive for your facility: 

A. If you have no handheld H2O2 sensor but a written protocol has been established by your organization 
or an authorized Halosil Distributor for the room or for the class of similar rooms using a handheld H2O2 
sensor, use the time established by that protocol. 
 
B. If you have a handheld H2O2 sensor but no protocol, reenter the room after at least 90 minutes with PPE 
to determine if the measured H2O2 level has dropped to about 1 ppm or below.

C. If no written protocol has been established and you have no H2O2 sensor, assume a waiting time of AT 
LEAST 110 MINUTES AFTER FOGGING. (110 minutes is the minimum wait time. Length of wait time increases 
with room size. See time chart below.) 

Minimum Wait Times

Fog Time   

Recommended MINIMUM Wait Time 

10 minutes 

110 minutes 

 

15 

 

120 

 

 

20 

 

130 

 

 

25 

 

140 

 

 

30 

 

150 

 

 

Once the reentry time has been reached or exceeded, it is recommended that you open all doors, windows 
(if any), unseal HVAC vents and restart your HVAC system to allow increased ventilation and airflow 
circulation in the room. Uncover smoke detectors.

Timer Setting 

ft

3

m

3

Fog Times 

(

based on room size)

HaloFogger® EXT Operation Manual_1911

    

50 - 75 

 

 

1 - 2 

 

                        1   

 

   80 - 150 

                  

3 - 4 

 

           

          2   

   155 - 225 

                    

4 - 6 

 

                       3   

   230 - 300 

                   

7 - 8 

 

           

          4   

  305 - 375 

                   

9 - 11   

           

          5   

  380 - 450 

                  

11 - 13   

           

          6  

  455 - 525 

                  

13 - 15   

           

          7 

  530 - 750 

                  

15 - 21   

                     10 

 755 - 1125 

                  

21 - 32             

       

        15   

1130 - 1500 

                  

32 - 42   

           

        20

1505 - 1875 

                  

43 - 53   

 

        25

1880 - 2250 

                  

53 - 64   

 

        30

minutes

Summary of Contents for HaloFogger EXT

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Operation Manual 110V 220V EXT 1911 EXT...

Page 2: ...n and dispensing disinfectant The room should be unoccupied Large Wheels For easy maneuvering Power Cord Connection Reservoir Drain High Precision Nozzle Dry mist of disinfectant is dispensed through...

Page 3: ...lashing or overfilling which could harm the user and or the device 12 Halosil International is not responsible for any injury or damage caused by using this device outside of the specific parameters d...

Page 4: ...ger EXT without the extended nozzle hose assembly fully connected Damage will occur Filling Instructions 1 Open the HaloFogger EXT Reservoir Door by lifting front edge of door 2 Locate the disinfectan...

Page 5: ...r wheel 4 Take the clear tubing provided and drop one end into the waste bottle 5 Working the adjustable ball joints of the nozzle assembly mounting arm point the nozzle straight down Then move the no...

Page 6: ...determine if the measured H2O2 level has dropped to about 1 ppm or below C If no written protocol has been established and you have no H2O2 sensor assume a waiting time of AT LEAST 110 MINUTES AFTER F...

Page 7: ...r data logger via Bluetooth The HaloLog App does not need to be connected to a fogger before a treatment run is started The on board data logger captures all of the operating data which can be reviewe...

Page 8: ...ll be displayed 4 To initiate a connection tap on any HaloFogger serial number displayed on the Halo List Screen When the connection is made the Run Events Screen will appear The top row of the screen...

Page 9: ...and total Run Time for that HaloFogger highlighted in GREEN The HaloLog data stored on the selected HaloFogger will download automatically after the Bluetooth handshake has been established which is...

Page 10: ...nts will identified BILLABLE as a default Events that are not treatments a test run for example can be identified as NON BILLABLE These events will not appear in the downloadable CSV file but will be...

Page 11: ...ddress A keyboard will appear to enter address ACTION Tap to email data The iDevice s email screen will open to confirm message ACTION Tap SEND in upper right corner of screen to send message Back up...

Page 12: ...o a HaloFogger 2 In the event that HaloLogs of the same HaloFogger have been downloaded to multiple devices If one user has made changes to the HaloLog for example added room building or operator info...

Page 13: ...remove Step 3 Separate Parts Remove Main Bolt from Nozzle Insert Soak both parts in soap and water Rinse parts thoroughly with water Step 4 Reassemble Nozzle Carefully insert the Main Bolt back into...

Page 14: ...power cord is plugged into both the fogger and the wall outlet Then check to see that the outlet is working The green status indicator light should be illuminated when properly set up The fuse is blow...

Page 15: ...sembly 0750 000 includes retainer cap nozzle insert main bolt and O ring Re Order Number Part Part Number 110V HaloFogger EXT US and Canada 0753 110EXT 220V HaloFogger EXT 0753 220EXT HaloMist All Pur...

Page 16: ...of room being treated CAUTION PRECAUCION DO NOT ENTER ENTERINO Room Fogging in Progress Treatment Date Start Time Estimated Room Re entry Time Refer to HaloMist Use Instructions to determine room re...

Page 17: ...was purchased and the unit s serial number Proof of purchase may be required If Halosil International determines that the fogger qualifies for warranty coverage a Return Merchandise Authorization RMA...

Page 18: ...uce infection rates at your facility by visiting www halosil com There you can find out more about the Halo Disinfection System download literature and case studies and find a distributor near you 91...

Reviews: