background image

PARTS LIST / STATION

*Spare or repair parts do not include mounting screws, if they are not 

listed on the description. Screws must be ordered separately.

Item No.

1
2

3
4
5
6
7
8

9

Part No.

B2461
B2462
B2482
B2463
B2317
B1084
B1028
B2464
B2465

B2466

Part Name

P.W.B./display
P.W.B./heat control
P.W.B./heat control
Radiation sheet
Insulation sheet
Switch
Knob
Cover
Chassis

Jack for footswitch

Description

 
100-120 V  With triac
220-240 V  With triac

With screw

With display window, 
membrane sheet

Item No.

10

11
12

13

14

Part No.

B2467
B2483
B2479
B2484
B2485
B2384
B2468
B1258
B2419
B2421
B2422
B2423
B2424
B2425
B2426
B2469

Part Name

Transformer
Transformer
Transformer
Transformer
Transformer
Power receptacle
Fuse 125V-5A
Fuse 250V-3.15A
Power cord, 3 core & American plug
Power cord, 3 core, no plug
Power cord, 3 core, BS plug
Power cord, 3 core, European plug
Power cord, 3 core, European plug
Power cord, 3 core, BS plug
Power cord, 3 core, Australian plug
Vacuum pump

Description

100 V
110 V
120 V
220-230 V
240 V

100-120 V
220-240 V

India
Korea
Eur.
U.K.

Item No.

15
16

17
18

19
20

21
22

Part No.

B2470
B2471

B2480

B2481

B2472
B2473

B2474
B2475

B2476
B2477

Part Name

Tube joint
Air pump

Air pump

Air pump

Sound-proof tank
Silicone tube

Tube connector
Silicone tube

Air flow meter
Handpiece holder

Description

With silicone tube
100 V, With high nut, nylon 
band, double-side tape
110-120 V, With high nut, 
nylon band, double-side tape
220-240 V, With high nut, 
nylon band, double-side tape

8 × 5 × 130   mm
0.3 × 0.2 × 5.1   in.
With silicone tube 
8 × 5 × 205   mm
0.3 × 0.2 × 8.1   in.

assembly

Item No.

1

Part No.

B2478B

Part Name

Foot-switch

Description

Option

*If you need item no. 23. Exhaust nozzle, contact your 

Hakko representative.

1

2

18

20

19

13

10

11

12

15

14

21

16

22

9

7

17

3

4

5

6

8

23

1

TIME

TEMP

PO

WER

OFF

ON

OFF

ON

UP

DO

WN

UP

DO

WN

AIR

AIR CONTR

OL

VA

CUUM

MODE

AU

TO

MANU

AL

REMO

VE

INST

ALL

Option

Truss screw
(Zn · black)
(M4 × 5) (16)

External tooth
lock washer
(nominal size 3)

Pan head screw
with washer
(w/Spring washer)
(M4 × 10) (4)

Pan head screw
with washer
(w/Spring, Plain washer)
(M3 × 6) (2)

Pan head screw
with washer
(w/Spring, Plain washer)
(M3 × 10) (2)

Pan head screw
with washer
(w/Spring washer)
(M4 × 6) (2)

External tooth
lock washer
(nominal size 4)
(2)

Spring washer
(nominal size 3) (5)

Truss screw
(M4 × 16) (4)

Pan head screw
with washer
(w/Spring washer)
(M3 × 6) (6)

Plain washer
polycarbonate 
(nominal size 5) (4)

Pan head screw
with washer
(w/Spring, Plain washer)
(M3 × 8)

Spacer
(M3 × 12) (5)

Hexagonal socket
set screw
(M3 × 3)

Foot-switch
(sold separately)

Pan head screw
with washer
(w/Spring washer)
(M3 × 6) (2)

20

19

Summary of Contents for 852

Page 1: ...re operating the Hakko 852 Keep this manual readily accessible for reference TABLE OF CONTENTS PACKING LIST SPECIFICATIONS 1 SAFETY INSTRUCTIONS 2 PART NAMES 3 PREPARATION ASSEMBLY AND ELECTRICAL CONN...

Page 2: ...each pad 5 mm 0 2 in Power cord Hakko 852 station 7 6 mm 0 3 in Name Power consumption Hakko 852 100V 300W 110V 360W 120V 410W 220V 550W 230V 600W 240V 650W Power consumption Capacity Control tempera...

Page 3: ...considered potentially dangerous Turn the power OFF when no longer using the Hakko 852 or when leaving it unattended Before replacing parts or storing the unit allow the unit to cool and then turn the...

Page 4: ...Sensor internal Pad Vacuum pipe Start button Vacuum button Vacuum pipe control knob Mode setting section Vacuum indicator Handpiece holder mounting screw Handpiece holder mounting screw Heater indicat...

Page 5: ...one second the current timer setting is displayed 4 Handpiece This knob controls the airflow Airflow setting section The airflow can be set within the range of 7 to 20 l min Set the airflow using the...

Page 6: ...c Loosen the nozzle mounting screw Pass the vacuum pipe through the nozzle hole and attach the nozzle Figure 4 d Tighten the nozzle mounting screw Figure 1 CAUTION Vacuum Pipe Do not use excessive fo...

Page 7: ...er switch ON CAUTION This product is ESD protected Be sure to use a grounded wall socket CAUTION When not in use place the hand piece on the holder 6 Using vacuum function inoperative nozzle see page...

Page 8: ...onditions have been established performing maintenance or executing a single operation Remove Mode AUTO See page 9 This mode is used when removing parts After starting the heating time can be set by s...

Page 9: ...air stops blowing and the temperature display reads When checking the temper ature setting Press the button for less than one second To change the temperature setting see Setting Changing the Tem pera...

Page 10: ...acuum automatically turns ON and the part is held by suction Lift the handpiece and remove the part from the P W B Figure 2 Releasing the Part Release the part by pressing the vacuum button for more t...

Page 11: ...p After five seconds the vacuum turns OFF and the part is released from suction Figure 3 Stop When the timer reaches 0 cooling begins Make sure the solder has hardened before lifting the handpiece Fig...

Page 12: ...egins to flash 3 EnterTENS digit Use the UP and DOWN buttons to select the desired value for the TENS digit Any value from 0 to 9 can be selected When the desired value is displayed press the button T...

Page 13: ...ection for more than one second The station goes into timer setting mode and the HUNDREDS digit flashes on the display indicating that the HUNDREDS digit can be entered 3 Enter the HUNDREDS digit Use...

Page 14: ...ter The adjustment range is 7 l min to 20 l min CAUTION Do not apply excessive force when turning the airflow control knob VACUUM MODE POWER TIME AIR TEMP AIR CONTROL OFF ON Turn clockwise to increase...

Page 15: ...hen it has blown continuously for a specified amount of time in manual mode Power to the heater is turned off and then the air is stopped after the handpiece cools When the station enters power save t...

Page 16: ...ater sensor connector and remove the heater CAUTION Do not apply excessive force to the vacuum pipe Measure the resistance value 1 Measure the resistance value a of the sensor The correct value is 0 2...

Page 17: ...switch is turned ON CHECK Is the power cord disconnected ACTION Connect it CHECK Is the fuse blown ACTION Investigate why the fuse blew and then replace the fuse If the cause can not be determined rep...

Page 18: ...A1257B SOP 11 21 0 43 0 83 11 7 0 46 21 0 83 A1259B SOP 13 28 0 51 1 1 13 5 0 53 A1260B SOP 8 6 18 0 34 0 71 8 7 0 34 19 0 75 A1261B QFP 20 20 0 78 0 78 21 0 83 21 0 83 A1262B QFP 12 12 0 47 0 47 12...

Page 19: ...OP 5 6 13 0 22 0 51 4 4 I D 0 17 4 8 0 19 10 0 39 5 7 0 22 15 0 59 7 2 0 28 16 0 63 A1134 SOP 7 5 18 0 3 0 7 7 2 0 28 19 0 75 A1142B Bent Single 1 5 3 0 06 0 12 45 1 5 0 0 6 I D 3 0 1 2 I D 10 5 A1325...

Page 20: ...Air pump Air pump Air pump Sound proof tank Silicone tube Tube connector Silicone tube Air flow meter Handpiece holder Description With silicone tube 100 V With high nut nylon band double side tape 1...

Page 21: ...39 B2452 A1434 A1435 B2453 B2454 B2455 B2456 B2457 B2458 B2459 B1354 B2460 B2507 Part Name Pad Pad Pipe Heating element Heating element Vacuum pipe Handle Vacuum pipe adjust knob Packing Terminal boar...

Page 22: ...DIAGRAM Hot air pump P W B Display Jack for foot switch Handpiece Terminal board Heater element Heater CA sensor P W B Heat control Vacuum pump Transformer AC15V Power receptacle Power switch P W B Tr...

Page 23: ...sg MALAYSIA HAKKO PRODUCTS SDN BHD MALAYSIA HEAD OFFICE NO 22 JALAN PEMBERITA U1 49 SEKSYEN U1 TEMASYA INDUSTRIAL PARK 40150 GLENMARIE SHAH ALAM SELANGOR DARUL EHSAN WEST MALAYSIA TEL 03 5569 5223 FA...