![background image](http://html1.mh-extra.com/html/hakko-electronics/852/852_instruction-manual_3307226019.webp)
18
Foot-switch jack
Foot-switch
(sold separately)
Insert the foot-switch plug into the
foot-switch jack on the back of the station.
●
FOOT-SWITCH
The foot-switch can be used to perform the
same operation as the start button and the
vacuum button on the handpiece.
A1124B Single
φ
2.5
(0.09)
φ
2.5 (I.D)
(0.09)
A1130 Single
φ
4.4
(0.17)
A1133 SOP 7.5
×
15
(0.3
×
0.59)
A1131 SOP 4.4
×
10
(0.17
×
0.39)
A1132 SOP 5.6
×
13
(0.22
×
0.51)
φ
4.4 (I.D)
(0.17)
4.8 (0.19)
10 (0.39)
5.7 (0.22)
15 (0.59)
7.2 (0.28)
16 (0.63)
A1134 SOP 7.5
×
18
(0.3
×
0.7)
7.2
(0.28)
19 (0.75)
A1142B Bent Single 1.5
×
3
(0.06
×
0.12)
45¡
1.5
(0.06) (I.D)
3
(0.12) (I.D)
10
5
A1325 Dual Single
φ
1.5
×
5-10
(0.06
×
0.2-0.39)
Adjustable Pitch
φ
1.5 (I.D)
(0.06)
5 (0.2)
10 (0.39)
The pitch
between the
two nozzles
is adjustable.
VACUUM FUNCTION INOPERATIVE NOZZLES.
CAUTION
Be sure not to use No. A1124 Single
φ
2.5 (0.09) and No. A1142 Bent Single 1.5 × 3 (0.06 × 0.12) nozzle
with the Hakko 852. These nozzles do not have space to blow hot air, using them with the 852 may result
in danger.